ICON System Faults
ICON
System Faults
The
ICON
System exhibits two types of faults:
Recoverable
and
Non-recoverable.
ICON
System faults
are visually indicated by the remote control, the switch panels, the gateway, and the 6-port hub LED’s.
ICON
System faults are also displayed on the
Faults
page of Evinrude
Diagnostics
and on the
NMEA
2000
gauges.
Recoverable Faults
Recoverable faults are Motion or Over-Current errors which occur on a throttle or shift actuator. A motion
error occurs when the
ESM
is attempting to move an actuator from one position to another, but the actu-
ator does not move. An over-current error occurs when the
ESM
is moving an actuator and the actuator
draws too much current.
When recoverable faults are detected the remote control continues to send shift, throttle, trim, and
start/stop commands as normal.
During a recoverable fault, the
ICON
System:
•
Flashes a gear LED of the affected engine
one time per second to indicate the gear position command
that caused the fault.
•
Sends a fault message to the outboard
EMM
. The
EMM
then sends a “Check Engine” message to the
NMEA 2000
gauges.
•
Stops shift or throttle actuator movement at the point where the fault occurred
•
Will NOT activate
S.A.F.E
.
When all control levers are put in NEUTRAL, the
ICON
System
•
Stops flashing the FORWARD and NEUTRAL gear LED’s
•
Continues to flash the NEUTRAL LED of the faulty engine one time per second
•
Allows shift or throttle actuator movement to continue up to the point where the fault occurred
Fault
Cause
Binnacle Control
LED’s (flashing)
CSM Remote Con-
trol Switch Panel
LED (flashing)
Control Lever
Position
FWD Shift
Motion or over-current
error occurred while mov-
ing shift actuator from NTL
to FWD
FWD
NTL
Move control
lever back to
NTL
REV Shift
Motion or over-current
error occurred while mov-
ing shift actuator from NTL
to REV
REV
NTL
Move control
lever back to
NTL
NTL Shift
Motion or over-current
error occurred while mov-
ing shift actuator from FWD
or REV to NTL
NTL
NTL
Move control
lever to original
position (FWD or
REV)
Throttle
Movement
Motion or over-current
error occurred while mov-
ing throttle actuator
when
in FWD or REV
FWD LED if lever
is in FWD
NTL
Move control
lever toward idle
and beyond the
position where
the fault
occurred
REV LED if lever
is in REV
NTL
Summary of Contents for EVINRUDE E-TEC BE225HGXABA
Page 163: ...Oiling System Oil Supply Diagrams 163 8 008208R Port Side View Starboard Side View ...
Page 165: ...Oiling System Oil Supply Diagrams 165 8 008432R Port Side View Starboard Side View ...
Page 167: ...Oiling System Oil Recirculation Diagrams 167 8 008207R Starboard View Port View ...
Page 251: ...Powerhead Powerhead Views 251 11 Powerhead Views Port Hose Routings 3 3 L models 007153 ...
Page 252: ...252 Powerhead Powerhead Views Starboard Hose Routings 3 3 L models 007154 ...
Page 253: ...Powerhead Powerhead Views 253 11 Port Hose Routings 3 4 L models 008503 ...
Page 254: ...254 Powerhead Powerhead Views Starboard Hose Routings 3 4 L models 008502 ...
Page 255: ...Powerhead Powerhead Views 255 11 Port 3 3 L models 008448 ...
Page 256: ...256 Powerhead Powerhead Views Starboard 3 3 L models 008449 ...
Page 257: ...Powerhead Powerhead Views 257 11 Port 3 4 L models 008441 ...
Page 258: ...258 Powerhead Powerhead Views Starboard 3 4 L models 008442 ...
Page 259: ...Powerhead Powerhead Views 259 11 Front 3 3 L models 008450 ...
Page 260: ...260 Powerhead Powerhead Views Front 3 4 L models 008439 ...
Page 261: ...Powerhead Powerhead Views 261 11 Rear 3 3 L models 007142 ...
Page 262: ...262 Powerhead Powerhead Views Rear 3 4 L models 008440 ...
Page 263: ...Powerhead Powerhead Views 263 11 Top 008438 ...
Page 264: ...264 Powerhead Powerhead Views Starboard ICON models 008504 ...
Page 269: ...Midsection Service Charts 269 12 Muffler 004117R ...
Page 320: ...S 322 ...