66
ELECTRICAL
CAUTION SYSTEM
CAUTION SYSTEM
Two caution systems alert the operator when an
abnormality occurs:
•
Over-revolution Caution
•
Low Oil Pressure Caution
•
Overheat Caution
* Remote models only
Self Test
The caution lamp turns ON two seconds after
starting engine.
On remote control models, the caution buzzer
sounds when ignition switch is turned ON. Buzzer
stops when engine starts and oil pressure switch
turns OFF.
Over-Revolution Caution System
The CDI unit engages the over-revolution limiter
above 5500 RPM.
•
If the engine is operated at a speed above 5500
RPM for more than 10 seconds, the engine
speed will be automatically lowered to approxi-
mately 3000 RPM by intermittent ignition.
•
If the operator decreases engine speed to less
than approximately 5500 RPM within 10 sec-
onds, the over-revolution caution control will be
cancelled.
•
During operation of the over-revolution caution
control, the caution lamp is ON.
To cancel the over-revolution caution control,
close the throttle to reduce engine speed below
approximately 2500 RPM for more than one sec-
ond.
IMPORTANT:
In NEUTRAL, the over-revolution
caution system activates at 3000 RPM and the
caution lamp does not light. To cancel the neutral
over-revolution caution control, close throttle com-
pletely for more than one second.
Caution Type
Lamp
Buzzer *
Rev
Limiter
Over-revolution
Yes
No
Yes
Low oil pressure
Yes
Yes
Yes
Overheat
Yes
Yes
Yes
1.
Caution lamp
005555
1