38
©2004,1998 Bruno Independent Living Aids, Inc.®
CRE-2100 NRUL 08-16-2004
VACATION/LONG-TERM STORAGE
If the stairway elevator will not be in use for an
extended period of time:
1.
Set the circuit breaker to OFF.
2.
Unplug the battery charger from the wall
outlet.
NOTE: Set the circuit breaker to OFF
before
unplugging the battery charger to avoid
causing battery discharge and/or premature
battery failure.
RETURNING THE UNIT TO SERVICE
1.
Set the circuit breaker to ON.
2.
Plug the battery charger into the wall outlet.
NOTE: The batteries may require recharging if the
unit remained OFF for an extended period
of time. Simply reconnect the charger to the
wall outlet (circuit breaker ON) and allow the
battery to fully recharge.
MAINTENANCE