CALL/SEND TRANSMITTER-RESIDENTIAL
MOUNTING THE STANDARD INFRARED CALL/
SEND TRANSMITTER
Mounting with bracket and hardware:
1. Mount the bracket to the back of the
transmitter using the (4) screws
provided.
2. Position the bracket/transmitter unit
in the mounting location on the wall
and mark the top and bottom bracket
holes.
3. Drill a pilot hole slightly smaller than
the anchors provided.
4. Gently pound the anchors into the wall
with a rubber mallet.
5. Position the bracket/transmitter unit
on the wall so that the top/bottom
bracket holes align with the anchors.
6. Secure the bracket/transmitter to the
wall using the screws provided.
TESTING THE CALL/SEND TRANSMITTER
1. Using the rocker switch on the seat arm-
rest, run the unit up and down the rail.
NOTE: The unit should travel
noticeably faster going up
than down.
2. Check for smooth operation and travel.
3. Now, using one of the remote call/send
transmitters, run the unit up and down
the rail.
4. Repeat Step 3 with the other transmitter.
5. Check for smooth operation and travel.
Soft Start Feature
The controller includes a
soft
start
feature which causes
a short delay between the
time the rocker switch on
the armrest is depressed
and the initiation of carriage
movement.
This is normal!
ELECTRICAL