AIR DELIVERY - CFM (Bottom Return With Filter)*

Unit

Operating Mode

CFM Airflow

External Static

External Static Pressure (ESP)

Size

Setting

Pressure Range*

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

036070

AIRFLOW (CFM)

†† Low Heat

735 (

615

)†

0-0.50

735

735

735

735

725

High Heat

1180 (

1060

)†

0-1.0

1160 1165 1175 1180 1180 1180 1180 1180 1180 1175

†† 1-1/2-Ton Cooling

525

0-0.50‡

525

525

525

525

510

†† 2-Ton A/C Cooling

700

0-0.50‡

700

700

700

695

685

2-1/2-Ton A/C Cooling

875

0-1.0‡

875

875

875

875

875

875

865

855

845

840

3-Ton A/C Cooling

1050

0-1.0‡

1050 1050 1050 1050 1050 1050 1050 1050 1045 1035

3-1/2-Ton A/C Cooling

1225

0-1.0

1205 1215 1225 1225 1225 1225 1225 1225 1225 1210

Maximum

1400

0-1.0

1395 1400 1400 1400 1400 1400 1400 1385 1360 1310

048090

Low Heat

985 (

825

)†

0-1.0

950

970

985

985

985

985

985

985

985

980

High Heat

1210 (

1090

)†

0-1.0

1190 1205 1210 1210 1210 1210 1210 1210 1210 1200

†† 1-1/2-Ton A/C Cooling

525

0-0.50‡

525

525

525

525

500

†† 2-Ton A/C Cooling

700

0-0.50‡

690

695

700

700

690

2-1/2-Ton A/C Cooling

875

0-1.0‡

830

855

875

875

875

875

870

865

850

820

3-Ton A/C Cooling

1050

0-1.0‡

1005 1025 1040 1050 1050 1050 1050 1050 1050 1050

3-1/2-Ton A/C Cooling

1225

0-1.0‡

1205 1220 1215 1225 1225 1225 1225 1225 1225 1220

4-Ton A/C Cooling

1400

0-1.0

1370 1385 1395 1400 1400 1400 1400 1400 1400 1380

Maximum

1600

0-1.0

1565 1580 1585 1595 1600 1600 1560 1520 1480 1430

060110***

Low Heat

1320 (

1110

)†

0-1.0

1275 1295 1315 1320 1320 1320 1320 1320 1320 1315

High Heat

1475 (

1330

)†

0-1.0

1460 1465 1475 1475 1475 1475 1475 1475 1465 1465

†† 2-Ton A/C Cooling

700

0-0.50‡

700

700

700

685

660

†† 2-1/2-Ton A/C Cooling

875

0-0.50‡

860

875

865

855

840

†† 3-Ton A/C Cooling

1050

0-0.50‡

1050 1050 1045 1050 1050

3-1/2-Ton A/C Cooling

1225

0-1.0‡

1185 1195 1215 1225 1225 1225 1225 1225 1225 1225

4-Ton A/C Cooling

1400

0-1.0‡

1385 1395 1400 1400 1400 1400 1400 1400 1400 1400

5-Ton A/C Cooling

1750

0-1.0‡

1710 1730 1745 1745 1750 1750 1750 1750 1745 1740

6-Ton A/C Cooling

2100

0-1.0

2090 2100 2100 2100 2095 2085 2065 2045 2020 1990

Maximum

2200

0-1.0

2200 2200 2200 2190 2185 2175 2155 2130 2085 2015

066135

Low Heat

1700 (

1430

)†

0-1.0

1700 1700 1700 1700 1700 1695 1700 1695 1685 1670

High Heat

1915 (

1725

)†

0-1.0

1900 1905 1915 1915 1915 1915 1915 1915 1915 1915

†† 2-Ton A/C Cooling

700

0-0.50‡

700

700

700

700

665

†† 2-1/2-Ton A/C Cooling

875

0-0.50‡

870

870

865

865

865

†† 3-Ton A/C Cooling

1050

0-0.50‡

1010 1030 1050 1050 1050

3-1/2-Ton A/C Cooling

1225

0-1.0‡

1155 1180 1200 1210 1220 1225 1225 1225 1225 1225

4-Ton A/C Cooling

1400

0-1.0‡

1395 1400 1400 1400 1400 1400 1400 1390 1375 1355

5-Ton A/C Cooling

1750

0-1.0‡

1740 1750 1750 1750 1735 1740 1735 1730 1715 1700

6-Ton A/C Cooling

2100

0-1.0

2075 2085 2090 2100 2100 2100 2090 2080 2055 2025

Maximum

2200

0-1.0

2180 2195 2200 2200 2200 2200 2185 2165 2140 2095

066155

Low Heat

1715 (

1440

)†

0-1.0

1715 1715 1715 1715 1715 1705 1710 1705 1705 1695

High Heat

1970 (

1775

)†

0-1.0

1955 1965 1965 1970 1970 1970 1970 1970 1970 1960

†† 2-Ton A/C Cooling

700

0-0.50‡

700

700

700

700

680

†† 2-1/2-Ton A/C Cooling

875

0-0.50‡

865

875

875

865

865

†† 3-Ton A/C Cooling

1050

0-0.50‡

1015 1020 1035 1045 1050

3-1/2-Ton A/C Cooling

1225

0-1.0‡

1160 1185 1215 1225 1225 1225 1225 1225 1225 1225

4-Ton A/C Cooling

1400

0-1.0‡

1385 1400 1400 1400 1400 1400 1395 1395 1380 1360

5-Ton A/C Cooling

1750

0-1.0‡

1745 1750 1750 1750 1745 1740 1745 1745 1740 1735

6-Ton A/C Cooling

2100

0-1.0

2055 2070 2080 2085 2095 2100 2100 2100 2090 2065

Maximum

2200

0-1.0

2175 2190 2200 2200 2200 2200 2200 2200 2180 2160

*

Actual external static pressure (ESP) can be determined by using the fan laws (CFM 

2

 proportional to ESP); such as, 

a system with 1180 CFM at 0.5 ESP would operate at cooling airflow of 1050 CFM at 0.4 ESP and low-heating airflow 
of 735 CFM at 0.19 ESP.

"Comfort mode" airflow values are shown in 

parenthesis

.  "Comfort mode" airflow is selected when the low-heat rise 

adjustment switch (SW1-3) is OFF and the comfort/efficiency switch (SW1-4) is ON.  Furnaces are shipped in this 
configuration.

Ductwork must be sized for high-heating CFM within the operational range of ESP.

††

Operation within the blank areas of the chart is not recommended because high-heat operation will be above 1.0 ESP.

***

All airflows on 110 size furnace are 5% less on side return only installations.

-8-

Summary of Contents for 315AAV

Page 1: ...s for AC and HP systems Matches CFM to cooling system at all static points Provides full Perfect Heat Perfect Humidity benefits including Super Dehumidify Four position furnace upflow horizontal right horizontal left downflow Thirteen different vent options Shorter in height only 331 3 tall Media Filter Cabinet included Microprocessor based smart control center Adapts heating stages to meet demand...

Page 2: ...ng 5 3 4 B Opening A02210 28 7 8 25 1 4 22 9 16 JUNCTION BOX LOCATION 7 8 DIA ACCESSORY 1 2 DIA THERMOSTAT WIRE ENTRY 3 15 16 LEFT HAND GAS ENTRY 33 5 16 24 7 8 5 1 2 7 8 DIA ACCESSORY 11 16 21 5 8 BOTTOM INLET 1 11 16 13 16 11 16 1 9 16 2 9 16 4 13 16 AIRFLOW 19 OUTLET 13 16 11 16 8 7 16 1 7 16 ALTERNATE JUNCTION BOX LOCATION TYP VENT OUTLET 5 PLACES TYP 3 3 4 1 1 2 DIA RIGHT HAND GAS ENTRY 1 2 D...

Page 3: ...d on special base Part No KGASB0201ALL Coil Assembly Part No CD5 or CK5 or Coil Casing Part No KCAKC 18 inches front clearance required for alcove Indicates supply or return sides when furnace is in the horizontal position Line contact only permissible between lines formed by intersections of the Top and two Sides of the furnace jacket and building joists studs or framing Clearance in inches Dégag...

Page 4: ...cent for each 1000 ft above sea level Refer to National Fuel Gas Code Table F4 or furnace Installation Instructions In Canada derate the unit 10 percent for elevations 2000 ft to 4500 ft above sea level Capacity in accordance with U S Government DOE test procedures Airflow shown is for bottom only return air supply in comfort mode as shipped For air delivery above 1800 CFM see Air Delivery table f...

Page 5: ...it KGANP2901ALL x x x x x Propane to Natural Gas Conversion Kit Single Kit KGAPN2301ALL x x x x x FACTORY AUTHORIZED DEALER INSTALLED ACCESSORIES 066135 036070 066155 048090 060110 s s s Gas Orifice Kit Qty 50 Size 42 KGAHA0150N42 Gas Orifice Kit Qty 50 Size 43 KGAHA0250N43 Gas Orifice Kit Qty 50 Size 44 KGAHA0350N44 Gas Orifice Kit Qty 50 Size 45 KGAHA0450N45 Gas Orifice Kit Qty 50 Size 46 KGAHA0...

Page 6: ...nflow installations must use Type B vent immediately after exiting the furnace except when KGAVG0101DFG is used in downflow position 4 Type B vent where required refer to Note 1 5 4 single wall vent must be used inside furnace casing and the KGAVG0101DFG Downflow Vent Guard Kit 6 Accessory Downflow Vent Guard Kit KGAVG0101DFG required in downflow installations with bottom vent configuration 7 Chim...

Page 7: ...TES 1 2 4 5 7 8 9 HORIZONTAL RIGHT A02069 SEE NOTES 1 2 4 7 8 9 HORIZONTAL RIGHT A02064 SEE NOTES 1 2 4 7 8 9 HORIZONTAL LEFT A02065 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL LEFT A02066 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL LEFT A02067 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL LEFT ...

Page 8: ... 0 2200 2200 2200 2190 2185 2175 2155 2130 2085 2015 066135 Low Heat 1700 1430 0 1 0 1700 1700 1700 1700 1700 1695 1700 1695 1685 1670 High Heat 1915 1725 0 1 0 1900 1905 1915 1915 1915 1915 1915 1915 1915 1915 2 Ton A C Cooling 700 0 0 50 700 700 700 700 665 2 1 2 Ton A C Cooling 875 0 0 50 870 870 865 865 865 3 Ton A C Cooling 1050 0 0 50 1010 1030 1050 1050 1050 3 1 2 Ton A C Cooling 1225 0 1 0...

Page 9: ...023 1059 1091 066135 Low Heat 1700 0 1 0 321 371 430 469 509 562 608 666 706 757 High Heat 1915 0 1 0 429 476 542 601 658 730 778 832 902 944 2 Ton A C Cooling 700 0 0 50 61 83 107 128 149 2 1 2 Ton A C Cooling 875 0 0 50 76 107 134 160 187 3 Ton A C Cooling 1050 0 0 50 103 135 174 208 240 3 1 2 Ton A C Cooling 1225 0 1 0 131 174 210 253 289 336 374 423 459 511 4 Ton A C Cooling 1400 0 1 0 201 250...

Page 10: ... 10 ...

Page 11: ... 11 ...

Page 12: ...NGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS PDS 315A 45 2 2003 Bryant Heating Cooling Systems 7310 W Morris St Indpls IN 46231 PRINTED IN U S A Catalog No 5231 500 06 03 Cancels 315A 45 1 ...

Reviews: