background image

 

7

 

furnace air filter be checked every 3 or 4 
weeks and cleaned if necessary.

If installed with factory-specified dis-
posable media filter, check or replace fil-
ter before each heating and cooling 
season. Replace disposable media filter 
at least once a year.

The air filter is normally located in the 
blower compartment. (See Fig. 2.) 
If air filter has been installed in another 
location, contact your dealer for instruc-
tions. To inspect, clean, and/or replace 
the air filter(s), follow these steps:

1. Turn off electrical supply to the 

furnace. (See Fig. 16.)

2. Remove main furnace door. 

(See Fig. 18.)

3. Remove blower access panel. 

(See Fig. 19.)

 

NOTE:

 

 It will be necessary to remove  

2 screws.

 

18

19

4. Remove air filter from furnace.

• AIR FILTER(S) LOCATED IN 

END OF FURNACE:

a. Slide filter retainer sideways until 

it is free of latch. (See Fig. 20.)

b. Slide air filter out of furnace. 

(See Fig. 21.)

20

21

• AIR FILTER LOCATED IN SIDE 

OF FURNACE:

a. Remove filter retainer from latch. 

(See Fig. 22.)

b. Gently remove air filter and care-

fully turn the dirty side up (if 
dirty) to avoid spilling dirt from 
the filter. (See Fig. 23.)

22

23

5. Inspect the filter. If torn, replace it.

NOTE:

 If washable filter that was 

shipped with the furnace has been 
replaced with an electronic air cleaner 
(EAC), refer to the EAC Owner’s Man-
ual for maintenance information.

6. If washable filter, wash filter (if 

dirty) in a sink, bathtub, or outside 
with a garden hose. Always use 
cold tap water. A mild liquid deter-
gent may be used if necessary. 
Spray water through filter in the 
opposite direction of airflow. 
Allow filter to dry.

7. Reinstall clean air filter.
8. Reinstall filter retainer.
9. Replace blower access panel and 

main furnace door.  Be sure to 
replace 2 screws in blower access 
panel. (See Fig. 24 and 25.) Turn 
on electrical supply to the furnace.

24

 

25

If your furnace air filter needs to be 
replaced, be sure to use a factory autho-
rized filter of the same size that was 
originally supplied. Use the furnace fil-
ter table and compare your furnace size 
with the proper filter size.

FURNACE AIR FILTER TABLE

 * Furnace with a side return-air inlet may have a dif-

ferent filter size. Measure the filter to obtain the 
correct size.

FURNACE 

CASING WIDTH 

(IN.)

FILTER SIZE*

(IN.)

FILTER TYPE

17-1/2

(1) 16 x 25 x 1

Cleanable

21

(1) 20 x 25 x 1

Cleanable

24-1/2

(1) 24 x 25 x 1

Cleanable

Summary of Contents for 345MAV

Page 1: ...reference Do not use this furnace if any part has been under water A flood damaged furnace is extremely dangerous Attempts to use the furnace can result in fire or explosion A qualified service agency...

Page 2: ...d on stan dard U S Department of Energy test procedures MODEL 345MAV FURNACE TABLE OF CONTENTS WELCOME TO A NEW GENERATION OF COMFORT 2 GENERAL FURNACE SAFETY 2 FURNACE COMPONENTS 3 SAFETY CONSIDERATI...

Page 3: ...re for added safety Condensate drain connection Collects moisture condensed from burned gases for disposal into home drain system Location in furnace varies Heavy duty blower Circulates air across the...

Page 4: ...s may be combustible This furnace contains SAFETY DEVICES which must be MANU ALLY RESET If the furnace is left un attended for an extended period of time have it checked periodically for proper operat...

Page 5: ...Replace main furnace door See Fig 12 8 Turn ON electrical supply to the furnace and wait 1 minute See Fig 13 9 Open the external manual gas valve See Fig 14 10 Set room thermostat to a tempera ture s...

Page 6: ...recautions that may apply With proper maintenance and care your furnace will operate economically and dependably Instructions for basic mainte nance are found on this and the following pages However b...

Page 7: ...g dirt from the filter See Fig 23 22 23 5 Inspect the filter If torn replace it NOTE If washable filter that was shipped with the furnace has been replaced with an electronic air cleaner EAC refer to...

Page 8: ...and remainder of furnace for dirt rust soot or scale 3 Inspect the combustion air and vent PVC pipes for sags holes cracks or disconnections Hori zontal portions of vent pipe must slope downward towa...

Page 9: ...uld be cleaned annually by a quali fied service agency Refer to the Ser vice and Maintenance Instructions for further information Examine the physical support of the furnace The support should be soun...

Page 10: ...furnace still fails to operate call your service representative For your convenience record the fur nace product and serial numbers on back page Should you ever require ser vice you will have ready ac...

Page 11: ...11...

Page 12: ...IN 46231 12 Printed in U S A Catalog No 5334 519 10 03 INSTALLATION DATA Date Installed Dealer Name Address City State Zip Telephone FURNACE Product No Model No Serial No AIR CONDITIONER OR HEAT PUMP...

Reviews: