—3—
DIMENSIONS—MODEL 361AAN
A96306
DIMENSIONS (In.)
* Filter rack provides transition from duct size to opening size.
† Duct sizes are ID dimensions for slipping over filter rack.
‡ Outlet of heat exchanger and elbow shipped with furnace is 6 in. Flue pipe may be reduced to 5-in. diameter for vent sizing.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (In.)
* Floor may be combustible.
AIR DELIVERY—CFM (Without Filters)
UNIT
SIZE
SHIP.
WT (Lb)
UNIT DIMENSIONS
DUCT SUPPLY
OPENING
FLUE
DIAMETER
SIDE RETURN
OPENING*
END (BOTTOM)
RETURN
OPENING
SIDE RETURN
DUCT SIZE†
END (BOTTOM)
RETURN DUCT
SIZE†
WIDTH
DEPTH HEIGHT
A
B
C
D
E
F
G
H
J
K
L
M
N
P
036075
215
22
30-1/2
48
20
17
6‡
15
25-1/4
20-1/8
17-1/16
18-1/4
25-1/4
20-1/4
25-1/4
036105
228
22
30-1/2
48
20
17
6‡
15
25-1/4
20-1/8
17-1/16
18-1/4
25-1/4
20-1/4
25-1/4
048125
254
22
35-1/2
48
20
22
6‡
15
30-1/4
20-1/8
22-1/16
18-1/4
30-1/4
20-1/4
30-1/4
060155
265
22
35-1/2
48
20
22
6
‡
15
30-1/4
20-1/8
22-1/16
18-1/4
30-1/4
20-1/4
30-1/4
UNIT APPLICATION
UPFLOW
HORIZONTAL
SIDES—Furnace
0
2
Supply Plenum and Warm-Air Duct Within 6 ft of Furnace
1
1
BACK
0
0
TOP— Furnace Casing or Plenum
2
2
Horizontal Warm-Air Duct Within 6 ft of Furnace
2
3
BOTTOM
0*
0*
FLUE PIPE— Horizontally or Below Pipe
4
4
Vertically Above Pipe
8
8
FRONT
8
24
UNIT
SIZE
BLOWER
MOTOR
HP
SPEED
EXTERNAL STATIC PRESSURE IN. WC
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
036075
1/3 PSC
High
1530
1475
1410
1340
1255
1170
1075
970
855
705
Medium
1240
1200
1150
1110
1065
1000
920
830
705
555
Low
870
850
830
805
765
720
660
590
480
360
036105
1/3 PSC
High
1635
1560
1500
1425
1365
1260
1165
1040
945
785
Medium
1470
1425
1365
1290
1220
1140
1030
935
825
695
Low
1280
1245
1205
1145
1085
1010
935
835
710
590
048125
1/2 PSC
High
1965
1915
1865
1805
1745
1665
1590
1515
1445
1345
Medium
1695
1645
1615
1565
1530
1465
1410
1335
1255
1165
Low
1340
1330
1320
1290
1270
1215
1180
1125
1045
990
060155
3/4 PSC
High
2240
2170
2085
1980
1935
1820
1750
1665
1590
1510
Medium
2000
1965
1890
1795
1755
1690
1625
1555
1480
1375
Low
1535
1495
1450
1420
1365
1330
1275
1205
1125
1035
J
N
P
B
E
M
D
A
F
OIL INLET
7
/
8
-IN.
DIA (2 PLACES)
BOTH SIDES
ELECTRICAL
CONNECTIONS
(TOP)
1
/
2
-IN. DIA
BOTH SIDES
(BOTTOM)
7
/
8
-IN.
DIA BOTH SIDES
H
B
K
G
KNOCK-OUT BOTH SIDES
FOR SIDE FLUE
C
E
21
9
⁄
16
″
13
9
⁄
16
″
2
″
12
1
⁄
16
″
1
″
1
″
1
″
3
1
⁄
16
″
2
9
⁄
16
″
4
″
ALTERNATE
OIL INLET
THROUGH SLOTS
L
SIDE
RETURN
AIR DUCT
END RETURN
AIR DUCT
SIDE
RETURN
AIR DUCT
11
15
⁄
16
″
CLEANOUT