—7—

 

DIMENSIONS—MODEL 363AAP

 

A96336

 

DIMENSIONS (In.)

 

*Filter rack provides transition from duct to opening size.
† Duct sizes are ID dimensions for slipping over filter rack.

 

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (In.)

 

* Floor may be combustible.

 

AIR DELIVERY—CFM (Without Filters)

 

UNIT

SIZE

SHIP

WT

(Lb)

UNIT DIMENSIONS

DUCT SUPPLY

OPENING

FLUE 

DIAMETER

SIDE RETURN

OPENING*

END (BOTTOM)

RETURN 

OPENING

SIDE RETURN

DUCT SIZE†

END (BOTTOM) 

RETURN

DUCT SIZE†

WIDTH

DEPTH HEIGHT

A

B

C

D

E

G

H

J

K

L

M

N

P

 

060210

385

26

42-1/2

54-3/4

24

29

7

17-3/4

37-1/4

24-1/8

29-1/16

20-1/4

38-1/4

24-1/4

38-1/4

 

UNIT APPLICATION

UPFLOW

HORIZONTAL

 

SIDES—Furnace

2

2

Supply Plenum and Warm-Air Duct Within 6 ft of Furnace

1

1

BACK

2

2

TOP— Furnace Casing or Plenum

2

2

Horizontal Warm-Air Duct Within 6 ft of Furnace

2

3

BOTTOM

0*

0*

FLUE PIPE— Horizontally or Below Pipe

9

9

Vertically Above Pipe

9

9

FRONT

24

24

 

UNIT

SIZE

BLOWER

MOTOR

HP

SPEED

EXTERNAL STATIC PRESSURE IN. WC

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

 

060210

3/4 PSC

High

2485

2395

2305

2250

2145

2075

1975

1885

1780

1675

Medium

2195

2125

2060

1990

1915

1860

1785

1700

1620

1525

Low

1640

1590

1540

1515

1460

1410

1350

1275

1190

1075

  

 

OIL INLET 

3

/

8

 IN. DIA

(2 PLCS) BOTH SIDES

ELECTRICAL CONNECTIONS
(TOP) 

1

/

2

 

IN. DIA BOTH SIDES

(BOTTOM) 

7

/

8

 

IN. DIA BOTH SIDES

11 

15

/

16

12 

1

/

16

1

1

2

FLUE
DIAMETER 

F

B

E

M

A

D

J

N

C

B

G

K

H

E

L

P

ALTERNATE OIL INLET
THROUGH SLOTS

REAR VIEW

CLEANOUT
PORTS

END

RETURN

AIR DUCT

CONTROL

BOX

SIDE RETURN
AIR DUCT

CLEANOUT PORTS

CLEANOUT PORTS

Summary of Contents for 361AAN

Page 1: ... 75 2 OIL FIRED FURNACES 361AAN 362AAN 363AAP Sizes 075 thru 210 361AAN Upflow Horizontal 362AAN Low Boy 363AAP Upflow Horizontal Large Capacity A N I N D EPENDENT LABOR A T O R Y T E S T IN G FOR PUBLIC SA F E T Y ama ...

Page 2: ...The constant low speed blower switch provides air circulation during off cycles for indoor air filtration DURABLE CABINET The casing is constructed of prepainted steel for years of attractiveness Filter and filter rack are provided with each furnace SPECIFICATIONS Capacity and AFUE in accordance with U S Government DOE test procedures Permissible limits of the voltage range at which the unit will ...

Page 3: ...num 2 2 Horizontal Warm Air Duct Within 6 ft of Furnace 2 3 BOTTOM 0 0 FLUE PIPE Horizontally or Below Pipe 4 4 Vertically Above Pipe 8 8 FRONT 8 24 UNIT SIZE BLOWER MOTOR HP SPEED EXTERNAL STATIC PRESSURE IN WC 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 036075 1 3 PSC High 1530 1475 1410 1340 1255 1170 1075 970 855 705 Medium 1240 1200 1150 1110 1065 1000 920 830 705 555 Low 870 850 830 805 765 720 ...

Page 4: ...d The constant low speed blower switch provides air circulation during off cycles for indoor air filtration DURABLE CABINET The casing is constructed of prepainted steel for years of attractiveness Filter provided with each furnace Capacity and AFUE in accordance with U S Government DOE test procedures Permissible limits of the voltage range at which the unit will operate satisfactorily Length sho...

Page 5: ...PIPE Horizontally or Below Pipe 4 Vertically Above Pipe 8 FRONT 8 UNIT SIZE BLOWER MOTOR HP SPEED EXTERNAL STATIC PRESSURE IN WC 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 036105 1 3 PSC High 1795 1735 1675 1605 1550 1485 1425 1350 1275 1220 Medium 1365 1335 1305 1275 1255 1215 1155 1105 1050 985 Low 995 965 945 925 900 870 825 775 725 670 048125 1 2 PSC High 1905 1845 1770 1695 1630 1565 1490 1425 1...

Page 6: ...tion easy HEAVY DUTY BLOWER Blower motors are PSC type and 3 speed The direct drive blowers eliminate belt adjustments in the field The constant low speed blower switch provides air circulation during off cycles for indoor air filtration DURABLE CABINET The casing is constructed of prepainted steel for years of attractiveness Filter and frame are provided with each furnace Capacity and AFUE in acc...

Page 7: ...um and Warm Air Duct Within 6 ft of Furnace 1 1 BACK 2 2 TOP Furnace Casing or Plenum 2 2 Horizontal Warm Air Duct Within 6 ft of Furnace 2 3 BOTTOM 0 0 FLUE PIPE Horizontally or Below Pipe 9 9 Vertically Above Pipe 9 9 FRONT 24 24 UNIT SIZE BLOWER MOTOR HP SPEED EXTERNAL STATIC PRESSURE IN WC 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 060210 3 4 PSC High 2485 2395 2305 2250 2145 2075 1975 1885 1780 ...

Page 8: ...ussed in this manual including Unit Familiarization Maintenance Installation Overview Operating Sequence A large selection of product theory and skills programs is available using popular video based formats and materials All include video and or slides plus companion book Classroom Service Training plus hands on the products in our labs can mean increased confidence that really pays dividends in ...

Reviews: