ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically)

 

1. Ball Bearing Fan Motor

 

A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.

SUGGESTED USE:  Required on all units where Low-Ambient Controller (full modulation feature) or MotorMaster

 

®

 

 Control has been added.

 

2. Coastal Filter

 

 

A filter designed to protect the condenser coil from salt damage without restricting airflow through the outdoor coil. 

SUGGESTED USE:  Geographic areas prone to salt spray. Used to meet job specifications where added coil protection is required.

 

3. Compressor Start Assist—Capacitor/Relay Type

 

 

Start capacitor and start relay gives ‘‘hard’’ boost to compressor motor at each start-up. 

SUGGESTED USE:  Installations where interconnecting tube length exceeds 50 ft.

Installations where outdoor design temperature exceeds 105°F (40.6°C).
Replacement installations with hard shutoff expansion valve on indoor coil.
Installations where Liquid-Line Solenoid Valve has been added.

 

4. Compressor Start Assist—PTC Type

 

 

Solid-state electrical device which gives a ‘‘soft’’ boost to compressor at each start-up. 

SUGGESTED USE:  Installations with marginal power supply.

 

5. Crankcase Heater

 

 

An electric resistance heater which mounts to the base of compressor to keep lubricant warm during off cycles. Improves compressor lubrication on 
restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control. 

SUGGESTED USE:  When interconnecting tube length exceeds 50 ft.

When unit will be operated below 55°F (12.8°C) outdoor air temperature. Use with Low-Ambient Controller.
All commercial installations.

 

6. Cycle Protector

 

 

Solid-state timing device which prevents compressor rapid recycling. Control provides an approximate 5-minute delay after power to the compressor has 
been interrupted for any reason, including normal room thermostat cycling. 

SUGGESTED USE:  Installations in areas where power interruptions are frequent.

Where user is likely to ‘‘play’’ with the room thermostat.
All commercial installations.
Installations where interconnecting tube length exceeds 50 ft.
High rise applications.

 

7. Evaporator Freeze Thermostat

 

 

An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions. 

SUGGESTED USE:  All units where Low-Ambient Controller has been added.

 

8. Filter Drier

 

A device for removing contaminants from refrigerant circulating in an air conditioner: 1-direction flow.

SUGGESTED USE:  All split-system air conditioners.

 

9. High-Pressure Switch

 

 

Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to 400 ± 10 
psig and resets at 298 ± 20 psig. Provides additional protection against compressor damage due to loss of outdoor airflow. To prevent rapid compressor 
recycling, Cycle Protector can be used with this switch.

SUGGESTED USE:  Installations exposed to very ‘‘dirty’’ outdoor air.

Installations where condenser inlet air temperature exceeds 125°F (51.7°C).

 

10. Liquid-Line Solenoid Valve (LSV)

 

 

An electrically operated shutoff valve to be installed at the outdoor or indoor unit (depending on tubing configuration), which stops and starts refrigerant 
liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle. 
Note: Compressor Start Assist—Capacitor/Relay Type must also be used. Do not use with hard shutoff TXV.

SUGGESTED USE:  For improved system performance in air conditioners for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.

In certain long line applications. Refer to Long-Line Application Guideline.

 

11. Low-Pressure Switch

 

 

Auto reset SPST switch activated by refrigerant pressure on low side of refrigerant circuit. Cycles compressor off if refrigerant pressure drops to about 27 
psig. Prevents indoor coil freeze-up due to loss of indoor airflow. Also, provides additional protection against compressor damage due to loss of refrigerant 
charge. To prevent rapid compressor recycling. Compressor Cycle Protector can be used with this switch. 

SUGGESTED USE:  Where indoor coil is exposed to ‘‘dirty’’ air.

All commercial installations.

 

12. MotorMaster

 

®

 

 Control

 

A fan speed control device activated by a temperature sensor. Designed to control condenser fan motor speed in response to the saturated, condensing 
temperature during operation in cooling mode only. For outdoor temperatures down to –20°F, it maintains condensing temperature at 100°F ±10°F.

SUGGESTED USE:  Cooling operation at outdoor temperatures below 55°F.

All commercial installations.

 

13. Outdoor Air Temperature Sensor

 

A device that allows the temperature at a remote location (outdoors) to be displayed at the thermostat.

SUGGESTED USE: All corporate programmable thermostats.

 

14. Sound Hood

 

 

Wrap-around sound attenuation cover for the compressor. Reduces the sound level by about 2 decibels.

SUGGESTED USE: Unit installed closer than 15 ft to quiet areas—bedrooms, etc.

Unit installed between 2 houses less than 10 ft apart.

 

15. Support Feet

 

 

Four stick-on plastic feet which raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base; 
minimizes corrosion. 

SUGGESTED USE:  Coastal installations. 

Windy areas or where debris is normally circulating.
Rooftop installations.

 

16. Thermostatic Expansion Valve (TXV) Kits

 

 

A modulating flow control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the 
evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Both hard shutoff and RPB type valves are available. Do not use hard shutoff 
TXV with Liquid-Line Solenoid Valve.

SUGGESTED USE:  For improved system performance in cooling mode for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.

Required for use on all zoning systems.

 

Summary of Contents for 593C Series

Page 1: ...g the compressor to eliminate sound transmission to the rest of the systems APPLICATION VERSATILITY The 593C can be combined with a wide variety of evaporator coils and blower packages to provide quiet dependable comfort Unit can be installed on a roof or at ground level on a slab EXTERNAL SERVICE VALVES Both service valves are brass front seating type with sweat connections Valves are externally ...

Page 2: ... 10 1 2 FIELD CONTROL SUPPLY CONN 1 9 16 C F N G A B M DIMENSIONS IN UNIT SIZE SERIES UNIT DIMENSIONS MINIMUM MOUNTING PAD DIMENSIONS A B C D E F G H K L M N 018 C D 23 13 16 22 1 2 26 3 16 4 1 8 7 1 8 13 13 16 18 3 8 5 8 12 1 2 15 1 2 10 1 2 2 3 8 22 x 26 024 C D 23 13 16 22 1 2 26 3 16 4 1 8 7 1 8 13 13 16 18 3 8 5 8 12 1 2 15 1 2 10 1 2 2 3 8 22 x 26 030 C D 27 13 16 22 1 2 26 3 16 4 1 8 7 1 8 ...

Page 3: ...TUBE DIAMETER IN 0 to 50 Ft Tube Length Long Line Applications 0 to 50 Ft Tube Length Long Line Applications Maximum Diameter 018 024 3 8 3 8 5 8 3 4 030 036 3 4 7 8 042 048 7 8 1 1 8 060 1 1 8 1 1 8 UNIT SIZE SERIES PISTON IDENTIFICATION NO 018 C D 55 024 C D 57 030 C D 67 036 C D 73 042 C D 78 048 C 82 060 C 96 CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI M A N U F A C ...

Page 4: ...ort Feet KSASF0101AAA Coastal Filter KAACF0701SML Time Delay Relay KAATD0601TDR Cycle Protector KSACY0101AAA Crankcase Heater KAACH1001AAA Start Assist Capacitor Relay Type KSAHS1001AAA Start Assist PTC Type KAACS0201PTC Sound Hood KSASH1101COP KSASH1201COP TXV Kit RPB KAATX0201RPB KAATX0301RPB KAATX0401RPB KAATX0501RPB TXV Kits Hard Shutoff KSATX0601HSO Low Pressure Switch KAALP0101LPS High Press...

Page 5: ...Millennium Scroll Millennium Scroll Temperature and Current Protection Internal Line Break Internal Line Break and Dome Thermostat Refrigerant Type and Amount Lb R 22 and 5 51 R 22 and 7 63 R 22 and 10 63 CONDENSER COIL and FAN Coil Face Sq Ft 12 2 15 2 18 3 Fins per In Rows Circuits 20 1 2 25 1 3 25 1 4 Fan Motor HP Type and RPM 1 4 PSC and 1100 Volts Hertz Phase 208 230 60 1 Condenser Airflow CF...

Page 6: ...sed with this switch SUGGESTED USE Installations exposed to very dirty outdoor air Installations where condenser inlet air temperature exceeds 125 F 51 7 C 10 Liquid Line Solenoid Valve LSV An electrically operated shutoff valve to be installed at the outdoor or indoor unit depending on tubing configuration which stops and starts refrigerant liquid flow in response to compressor operation Maintain...

Page 7: ...on feature and MotorMaster Control only SOUND POWER dBA ACCESSORY REQUIRED FOR LOW AMBIENT APPLICATIONS Below 55 F REQUIRED FOR LONG LINE APPLICATIONS Over 50 Ft REQUIRED FOR SEA COAST APPLICATIONS Within 2 Miles Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Winter Start Control Yes No No Accumulator No No No Compressor Start Assist Capacitor and Relay Yes Yes No MotorMaster C...

Page 8: ... 50 CC5A CD5AW024 23 000 NONE 10 00 10 20 10 20 CC5A CD5AW030 23 000 NONE 10 10 10 50 10 50 CE3AA024 23 200 NONE 10 00 10 20 10 20 CE3AA030 23 400 NONE 10 10 10 50 10 50 CF5AA024 23 000 NONE 10 10 10 50 10 50 CK3BA024 23 000 NONE 10 00 10 20 10 20 CK3BA030 23 000 NONE 10 00 10 50 10 50 CK5A CK5BA024 23 000 NONE 10 00 10 20 10 20 CK5A CK5BA030 23 000 NONE 10 00 10 50 10 50 CK5A CK5BW024 23 000 NONE...

Page 9: ... 11 11 10 05 CK5A CK5BW030 28 000 TDR 11 11 9 75 COILS 315 A J AV048090 VARIABLE SPEED FURNACE CC5A CD5AA030 28 000 TDR 11 11 9 85 CC5A CD5AA036 29 000 TDR 11 11 10 15 CC5A CD5AW030 28 000 TDR 11 11 9 85 CC5A CD5AW036 29 000 TDR 11 11 10 15 CE3AA030 28 000 TDR 11 11 9 95 CE3AA036 28 600 TDR 11 11 10 05 CK3BA030 28 000 TDR 11 11 9 85 CK3BA036 29 000 TDR 11 11 10 15 CK5A CK5BA030 28 000 TDR 11 11 9 ...

Page 10: ...LS 315 A J AV048090 VARIABLE SPEED FURNACE CC5A CD5AA036 33 000 TDR 11 11 9 85 CC5A CD5AA042 33 000 TDR 11 11 9 95 CC5A CD5AW036 33 000 TDR 11 11 9 85 CE3AA036 32 600 TDR 10 5 10 5 9 75 CE3AA042 33 000 TDR 11 11 9 95 CK3BA036 33 000 TDR 11 11 9 85 CK3BA042 33 000 TDR 11 11 9 9 CK5A CK5BA036 33 000 TDR 11 11 9 85 CK5A CK5BA042 33 000 TDR 11 11 9 9 CK5A CK5BE042 33 000 TDR 11 11 9 95 CK5A CK5BT036 3...

Page 11: ...CC5A CD5AC048 39 000 NONE 10 00 10 50 10 50 CC5A CD5AW042 39 500 NONE 10 00 10 20 10 20 CC5A CD5AW048 40 000 NONE 10 10 10 50 10 50 CD5AA048 40 000 NONE 10 10 10 50 10 50 CE3AA042 39 500 NONE 10 00 10 20 10 20 CE3AA048 39 500 NONE 10 10 10 50 10 50 CF5AA048 40 000 NONE 10 10 10 50 10 50 CK3BA042 39 500 NONE 10 00 10 20 10 20 CK3BA048 40 000 NONE 10 10 10 50 10 50 CK5A CK5BA042 39 500 NONE 10 00 10...

Page 12: ...ARIABLE SPEED FURNACE CK3BA042 39 500 NONE 10 50 10 50 CK5A CK5BN042 38 500 NONE 10 50 10 50 COILS 355MAV042080 VARIABLE SPEED FURNACE CC5A CD5AA042 40 000 NONE 11 00 11 00 CK3BA042 39 500 NONE 10 50 10 50 CK3BA048 39 500 NONE 10 50 10 50 CK5A CK5BA042 39 500 NONE 10 50 10 50 CK5A CK5BA048 39 500 NONE 10 50 10 50 COILS 355MAV060080 VARIABLE SPEED FURNACE CK3BA042 39 500 NONE 10 50 10 50 CK3BA048 3...

Page 13: ... CD5AA048 45 500 TDR 10 5 10 5 9 7 CE3AA048 45 500 TDR 10 5 10 5 9 7 CE3AA060 46 500 TDR 11 11 10 CK3BA048 45 500 TDR 10 5 10 5 9 7 CK3BA060 46 500 TDR 11 11 9 95 CK5A CK5BA048 45 500 TDR 10 5 10 5 9 7 CK5A CK5BA060 46 500 TDR 11 11 9 95 CK5A CK5BT048 45 500 TDR 10 5 10 5 9 7 CK5A CK5BT060 46 500 TDR 11 11 9 95 CK5A CK5BW048 45 500 TDR 10 5 10 5 9 7 CK5A CK5BX060 47 000 TDR 11 11 10 15 COILS 315 A...

Page 14: ... 20 10 50 10 50 CK3BA060 54 500 NONE 10 00 10 20 10 20 CK5A CK5BA060 54 500 NONE 10 00 10 20 10 20 CK5A CK5BN060 54 500 NONE 10 00 10 20 10 20 CK5A CK5BX060 57 000 NONE 10 20 10 50 10 50 F A B 4 A B N F B 060 57 500 TDR 10 00 10 00 FB4 A B NB070 58 500 TDR 10 50 10 50 FC4 B C NB070 58 500 TDR TXV 10 50 FC4 B C N F B 060 57 500 TDR TXV 10 00 FG3AAA060 56 500 NONE 10 20 10 50 10 50 FK4 C D NB006 58 ...

Page 15: ...9 16 9 8 95 2 09 15 6 8 51 2 20 67 18 6 13 1 1 72 17 5 12 6 1 83 16 3 12 2 1 93 15 2 11 7 2 03 14 0 11 2 2 13 62 16 8 15 8 1 68 15 8 15 2 1 78 14 7 14 5 1 87 13 7 13 7 1 97 12 7 12 7 2 06 57 16 2 16 2 1 67 15 4 15 4 1 77 14 6 14 6 1 87 13 7 13 7 1 97 12 9 12 9 2 06 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Unit Size Cooling Indoor Section Unit Size Cooli...

Page 16: ...2 37 21 7 21 6 2 50 20 4 20 4 2 63 19 2 19 2 2 75 18 0 18 0 2 88 57 22 7 22 7 2 36 21 6 21 6 2 49 20 4 20 4 2 62 19 2 19 2 2 75 18 0 18 0 2 88 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Unit Size Cooling Indoor Section Unit Size Cooling Capacity Power Capacity Power CC5A CD5AA 024 1 00 1 00 CC5A CD5AW 024 0 99 0 91 030 1 00 1 00 030 1 00 0 90 CC5A CD5AW 0...

Page 17: ... 92 036 1 01 1 01 036 1 02 0 93 CC5A CD5AW 030 1 00 1 00 CK3BA 030 1 00 0 93 CD5AW 036 1 01 1 01 036 1 04 0 93 CE3AA 030 0 99 1 00 CK5A CK5BA 030 1 00 0 93 036 1 01 1 01 036 1 04 0 93 CF5AA 036 1 01 1 01 CK5A CK5BW 030 1 00 0 93 CK3BA 030 1 00 1 00 036 1 04 0 93 036 1 01 1 01 COILS 355MAV042040 VARIABLE SPEED FURNACE CK5A CK5BA 030 1 00 1 00 CC5A CD5AA 030 1 01 0 95 036 1 01 1 01 CK3BA 030 1 01 0 ...

Page 18: ... CD5AW 042 1 00 1 00 042 0 99 0 92 CD5AW 036 1 00 1 00 CK5A CK5BW 036 0 99 0 92 CE3AA 036 0 99 1 00 COILS 315 A J AV066110 VARIABLE SPEED FURNACE 042 1 00 1 00 CC5A CD5AA 036 0 99 0 92 CF5AA 036 1 00 1 00 042 0 99 0 91 CK3BA 036 1 00 1 00 CC5A CD5AW 036 0 99 0 92 042 1 00 1 00 042 0 99 0 91 CK5A CK5BA 036 1 00 1 00 CE3AA 036 0 98 0 91 042 1 00 1 00 042 0 99 0 91 CK5A CK5BN 036 0 92 0 97 CK3BA 036 ...

Page 19: ... 3 71 27 8 27 8 3 90 26 2 26 2 4 10 1350 72 40 8 21 4 3 56 38 5 20 6 3 80 36 1 19 7 4 03 33 6 18 9 4 25 31 4 18 1 4 47 67 37 2 27 9 3 47 35 0 27 0 3 69 32 8 26 1 3 91 30 6 25 3 4 11 28 3 24 3 4 29 62 34 0 33 5 3 38 32 1 32 1 3 59 30 4 30 4 3 80 28 6 28 6 4 00 26 9 26 9 4 20 57 33 7 33 7 3 38 32 1 32 1 3 59 30 4 30 4 3 80 28 6 28 6 4 00 26 9 26 9 4 21 Multipliers for Determining the Performance Wit...

Page 20: ...y Power CC5A CD5AA 042 1 00 1 00 CD5AA 048 1 00 0 93 CC5A CD5AC 048 0 99 1 00 CE3AA 042 0 99 0 92 CC5A CD5AW 042 1 00 1 00 048 1 00 0 93 048 1 01 1 00 CK3BA 042 0 99 0 93 CE3AA 042 1 00 1 00 048 1 00 0 93 048 1 00 1 00 CK5A CK5BA 042 0 99 0 92 CF5AA 048 1 01 1 00 048 1 00 0 93 CK3BA 042 1 00 1 00 CK5A CK5BT 042 0 99 0 93 048 1 01 1 00 048 1 00 0 93 CK5A CK5BA 042 1 00 1 00 CK5A CK5BW 048 1 00 0 93...

Page 21: ... 4 74 57 37 3 37 3 3 83 35 5 35 5 4 05 33 7 33 7 4 28 31 9 31 9 4 51 30 1 30 1 4 73 1575 72 46 5 24 3 4 19 43 8 23 3 4 43 41 2 22 4 4 67 38 4 21 4 4 90 35 8 20 6 5 14 67 42 5 31 7 4 06 40 0 30 7 4 29 37 5 29 7 4 52 35 1 28 8 4 74 32 6 27 8 4 96 62 38 9 38 1 3 95 36 7 36 6 4 17 34 8 34 8 4 40 32 8 32 8 4 63 30 9 30 9 4 86 57 38 5 38 5 3 94 36 6 36 6 4 16 34 7 34 7 4 40 32 8 32 8 4 63 30 9 30 9 4 85...

Page 22: ...48 0 98 0 93 CC5A CD5AC 048 0 98 0 99 060 1 00 0 93 CC5A CD5AW 048 1 00 1 00 CK5A CK5BA 048 0 98 0 93 060 1 03 1 01 060 1 00 0 93 CD5AA 048 1 00 1 00 CK5A CK5BT 048 0 98 0 93 CE3AA 048 1 01 1 00 060 1 00 0 93 060 1 04 1 02 CK5A CK5BW 048 0 98 0 93 CF5AA 048 1 00 0 99 CK5A CK5BX 060 1 01 0 92 CK3BA 048 1 00 1 00 COILS 315 A J AV066135 VARIABLE SPEED FURNACE 060 1 00 1 01 CC5A CD5AA 060 0 99 0 94 CK...

Page 23: ...5 68 37 7 37 7 6 17 57 44 7 44 7 4 37 43 1 43 1 4 76 41 4 41 4 5 20 39 6 39 6 5 67 37 7 37 7 6 17 1750 72 56 2 28 7 4 69 53 8 27 8 5 08 51 2 26 9 5 52 48 5 25 9 6 00 45 7 24 9 6 51 67 51 4 37 0 4 57 49 1 36 1 4 96 46 7 35 1 5 40 44 2 34 2 5 87 41 6 33 1 6 37 62 46 8 44 7 4 47 44 7 43 5 4 86 42 6 42 2 5 29 40 5 40 5 5 76 38 5 38 5 6 26 57 45 8 45 8 4 45 44 1 44 1 4 85 42 3 42 3 5 28 40 4 40 4 5 76 ...

Page 24: ...22 43 8 43 8 7 86 2000 72 68 1 34 5 5 98 64 9 33 3 6 52 61 6 32 1 7 11 58 1 30 9 7 74 54 4 29 6 8 43 67 62 3 44 2 5 82 59 3 43 0 6 35 56 2 41 8 6 93 53 0 40 5 7 56 49 5 39 2 8 22 62 56 8 53 4 5 69 54 1 52 0 6 21 51 3 50 4 6 78 48 5 48 4 7 39 45 5 45 5 8 04 57 55 2 55 2 5 65 53 1 53 1 6 18 50 8 50 8 6 76 48 4 48 4 7 39 45 4 45 4 8 04 2250 72 69 0 35 8 6 10 65 7 34 7 6 64 62 3 33 4 7 23 58 7 32 2 7 ...

Page 25: ...1 1 85 1 99 2 12 2 25 2 35 2 44 TCG 38 4 36 3 34 1 31 7 29 4 27 0 24 7 55 SDT 95 3 102 0 110 0 118 0 127 0 135 0 144 0 KW 1 76 1 91 2 06 2 20 2 34 2 46 2 56 593C030 C D TCG 30 2 27 9 25 6 23 4 21 3 19 3 17 3 30 SDT 81 3 90 5 99 8 109 0 118 0 128 0 137 0 KW 1 88 2 02 2 15 2 27 2 36 2 44 2 50 TCG 33 5 31 0 28 6 26 3 24 0 21 8 19 7 35 SDT 83 4 92 5 102 0 111 0 120 0 129 0 139 0 KW 1 93 2 09 2 24 2 37...

Page 26: ...4 3 68 4 05 4 45 4 87 TCG 48 7 46 7 44 5 42 3 40 1 37 7 35 2 35 SDT 81 8 91 5 101 0 111 0 121 0 131 0 140 0 KW 2 81 3 09 3 39 3 74 4 12 4 53 4 96 TCG 53 1 50 9 48 7 46 4 43 9 41 4 38 8 40 SDT 83 7 93 3 103 0 113 0 123 0 132 0 142 0 KW 2 86 3 14 3 45 3 80 4 19 4 60 5 05 TCG 57 8 55 5 53 1 50 6 48 0 45 3 42 5 45 SDT 85 8 95 3 105 0 115 0 124 0 134 0 144 0 KW 2 92 3 20 3 52 3 87 4 26 4 68 5 14 TCG 62...

Page 27: ...refrigerant tube lengths of 50 to 175 ft or 20 ft vertical differential consult Long Line Application Guideline available from equipment distributor 7 Crankcase heater required when interconnecting refrigerant tube length exceeds 50 ft 8 If any refrigerant tubing is buried provide a minimum 6 in vertical rise to the valve connections at the unit Refrigerant tubing lengths up to 36 in may be buried...

Page 28: ... Unit Cabinet Unit cabinet will be constructed of galvanized steel bonderized and coated with a powder coat paint Fans Condenser fan will be direct drive propeller type discharging air upward Air Cooled Split System Air Conditioner 593C 1 1 2 to 5 Tons Nominal Condenser fan motors will be totally enclosed 1 phase type with class B insulation and permanently lubricated bearings Shafts will be corro...

Reviews: