21
INSTALL CLAMPS ON DRAIN TUBE
ATTACH DRAIN TUBE TO CONDENSATE
DRAIN TRAP
PULL DRAIN STUB
THROUGH CASING
OPEN SPRING CLAMP
INSERT FACTORY
ï
SUPPLIED 1/2
ï
IN. CPVC
TO 3/4
ï
IN. PVC ADAPTER OR 1/2
ï
IN. CPVC PIPE
*CLAMP MAY BE LOCATED ON OUTSIDE OF DRAIN
TUBE
A11342A
Fig. 15
−
Formed Rubber Drain Grommet
A11581
Fig. 16
−
Modify Rubber Drain Elbow
Remove knockout.
Install grommet before
relocating condensate
trap.
NOTE: Trap grommet is required only for direct-vent
applications.
A11582
Fig. 17
−
Horizontal Drain Trap Grommet
ATTACH ELBOW TO
CONDENSATE TRAP
CUT FORMED END OFF
CONDENSATE DRAIN
ELBOW
CONNECT SHORT END OF
’Z’ PIPE TO MODIFIED
DRAIN ELBOW
FORMED END OF GROMMET. OPEN
SPRING CLAMP, INSERT 1/2
ï
IN. TO 3/4
ï
IN.
CPVC TO PVC ADAPTER OR CPVC PIPE
FORMED END
OF GROMMET
FACTORY SUPPLIED
1/2
ï
IN. CPVC TO 3/4
ï
IN.
PVC ADAPTER
NOTE: Remove Inducer Housing for easier access, if desired.
MODIFIED DRAIN ELBOW CON-
NECT TO CONDENSATE TRAP
AND ’Z’ PIPE
TOP VIEW
DRAIN ELBOW “Z” DISCHARGE PIPE FOR LEFT SIDE
DRAIN IS ROUTED BEHIND INDUCER
FRONT VIEW
LEFT SIDE DRAIN PIPE ORIENTATION FOR CONDENSATE DISCHARGE
A170128
Fig. 18
−
Drain Trap Connection and Routing
(Appearance may vary)
INSTALLATION
Cabinet air leakage is less than 2% at 1.0 in. W.C. Cabinet air
leakage is less than 1.4% at 0.5 in. W.C. when tested in accor-
dance with ASHRAE Standard 193.
NOTICE
Upflow Installation
NOTE:
The furnace must be pitched as shown in Fig. 26 for
proper condensate drainage.
Supply Air Connections
For a furnace not equipped with a cooling coil, the outlet duct shall
be provided with a removable access panel. This opening shall be
accessible when the furnace is installed and shall be of such a size
that the heat exchanger can be viewed for possible openings using
light assistance or a probe can be inserted for sampling the air
stream. The cover attachment shall prevent leaks.
Connect supply
−
air duct to flanges on furnace supply
−
air outlet.
Bend flange upward to 90
with wide duct pliers. See Fig.
22.
The supply
−
air duct must be connected to ONLY the furnace
supply
−
outlet
−
air duct flanges or air conditioning coil casing
(when used). DO NOT cut main furnace casing side to attach
supply air duct, humidifier, or other accessories. All supply side
accessories MUST be connected to duct external to furnace main
casing.
912S