background image

4

MODEL NUMBER NOMENCLATURE

98

6

T

A

30

040

V

14

A

--

A

S - Single Stage
T - Two Stage
M - Modulating

S - Standard
E - Energy Efficient
V - Variable Speed

14 - 14.2”
17 - 17.5”
21 - 21.0”
24 - 24.5”

91 - Legacy
92 - Preferred
98 - Evolution

Voltage

L - Low NOx

1 - 2

Family/Tier

3

Base Eff.

Htg. Stages

4

5

Major Series

6 - 7

Clg. Cap.

Htg. Cap.

8 - 10

Motor

11

12 - 13

Width

14

Voltage

15

Features

Minor Series

16

Major Series

24 -  800 CFM
30 - 1000 CFM
36 - 1200 CFM
42 - 1400 CFM
48 - 1600 CFM
54 - 1800 CFM
60 - 2000 CFM
66 - 2200 CFM
(@ 0.5” ESP)

040= 40,000 BTU 

060= 60,000 BTU 
080= 80,000 BTU 

100=100,000 BTU 

120=120,000 BTU
140=140,000 BTU 

Not all familes have these models.

0 - +90 AFUE
2 - +92 AFUE
3 - +93 AFUE
5 - +95 AFUE
6 - +96 AFUE
7 - +97 AFUE

Example of a Model Number

A12374

FURNACE COMPONENTS

RATING PLATE NOT SHOWN

(LOCATED ON BLOWER DOOR)

GAS VALVE

MAIN LIMIT SWITCH

(BEHIND GAS VALVE)

REPRESENTATIVE DRAWING ONLY, SOME MODELS MAY VARY IN APPEARANCE.

ELECTRICAL JUNCTION

BOX (IF REQUIRED, 

LOCATION MAY VARY)

MEDIA CABINET

OPERATING INSTRUCTIONS

NOT SHOWN (LOCATED ON

MAIN FURNACE DOOR, SEE 

OPERATING INSTRUCTIONS 

INSIDE DOOR FIGURE).

FURNACE

CONTROL

BOARD

MANUAL RESET

ROLLOUT SWITCH

FLAME

SENSOR

MANUAL RESET

ROLLOUT SWITCH

GAS BURNER

HOT SURFACE

IGNITER

INDUCER MOTOR

ASSEMBLY

BLOWER AND

MOTOR

CAPACITOR/

POWER CHOKE

(IF USED)

BLOWER DOOR

SAFETY SWITCH

A11408

912SC

Summary of Contents for 912SC

Page 1: ...eight 35 cabinet short enough for taller coils but still allows enough room for service S Silicon Nitride Perfect Lightt Hot Surface Igniter S Aluminized steel primary heat exchanger S Stainless steel...

Page 2: ...product a design with more than ten years of field proven performance and success These innovations paired with the continuation of a crimped no weld seam create an efficient robust design for this e...

Page 3: ...970 2050 Cooling Capacity tons 400 CFM ton 2 5 2 5 2 5 3 5 4 4 5 3 5 5 5 350 CFM ton 2 5 3 3 4 4 5 5 0 4 0 5 5 5 5 Direct Drive Motor Type Permanent Split Capacitor PSC Direct Drive Motor HP 0 3 0 5 0...

Page 4: ...U 120 120 000 BTU 140 140 000 BTU Not all familes have these models 0 90 AFUE 2 92 AFUE 3 93 AFUE 5 95 AFUE 6 96 AFUE 7 97 AFUE Example of a Model Number A12374 FURNACE COMPONENTS RATING PLATE NOT SHO...

Page 5: ...Nat Gas LH32DB202 D D D D D D D D D Gas Orifice Kit 44 Nat Gas LH32DB200 D D D D D D D D D Gas Orifice Kit 45 Nat Gas LH32DB205 D D D D D D D D D Gas Orifice Kit 46 Nat Gas LH32DB208 D D D D D D D D...

Page 6: ...nge 3 5 397 1485 1470 1455 1430 1390 1340 1280 1205 1120 1035 Blue 3 2 5 426 1120 1110 1100 1090 1065 1035 990 935 870 805 Red 3 2 0 433 940 920 910 890 865 830 790 745 690 625 048100 SIDE BOTTOM Blac...

Page 7: ...Temp C Unit Size 40 000 BTUH 60 000 BTUH Uninsulated 3 8 in Insulation 1 2 in Insulation Uninsulated 3 8 in Insulation 1 2 in Insulation Pipe Dia mm 38 51 64 38 51 64 38 51 64 38 51 64 76 38 51 64 76...

Page 8: ...ize 40 000 Outlet choke required under 10 ft TEVL 60 000 80 000 100 000 120 000 140 000 Altitude meters Pipe Dia mm 38 51 64 38 5 64 76 38 51 64 76 102 51 64 76 102 64 76 102 64 76 102 0 610 6 26 57 6...

Page 9: ...eters of PVC ABS pipe VERIFY FROM VENT MANUFACTURER S INSTRUCTIONS Can this application use 60 mm O D polypropylene vent piping If not what size piping can be used Measure the required linear length o...

Page 10: ...PLY AIR A10490 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS POSITION CLEARANCE Rear 0 0 mm Front Combustion air openings in furnace and in structure 1 in 25 mm Required for service 24 in 610 mm All Sid...

Page 11: ...1 2 YES YES NO YES 60 000 14 3 16 YES YES NO YES 17 1 2 YES NO NO YES 80 000 17 1 2 YES YES NO YES 21 YES YES NO YES 100 000 21 YES YES NO YES 120 000 24 1 2 YES YES NO YES INPUT CASING WIDTH INCHES...

Page 12: ...5 8 600 2 24 1 2 622 Furnace with or without Cased Coil Assembly or Coil Box 22 1 8 562 19 483 23 3 4 603 20 5 8 600 1 The plenum should be constructed 1 4 in 6 mm smaller in width and depth than the...

Page 13: ...SUPPLIED DISCONNECT AUXILIARY J BOX 24 V TERMINAL BLOCK THREE WIRE HEATING ONLY FIVE WIRE NOTE 1 NOTE 2 FIELD SUPPLIED DISCONNECT CONDENSING UNIT TWO WIRE FURNACE C O N T R O L R G COM W C R G Y GND...

Page 14: ...S IN INCH MM 22 2 7 8 7 8 22 2 POWER CONN AIR FLOW SEE NOTE 3 NOTES 1 Doors may vary by model 2 Minimum return air openings at furnace based on metal duct If flex duct is used see flex duct manufactur...

Page 15: ...accessory highly efficient Media Filter is available as an option _____________ Media Filter Casing Casing shall be of 030 in thickness minimum pre painted steel Draft Inducer Motor Draft inducer mot...

Page 16: ...e or change at any time specifications or designs without notice and without incurring obligations E2014 Bryant Heating Cooling Systems D 7310 W Morris St D Indianapolis IN 46231 Edition Date 10 14 Re...