background image

16

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

E

2012 Bryant Heating & Cooling Systems

D

7310 W. Morris St.

D

Indianapolis, IN 46231

Printed in U.S.A.

Edition Date: 01/12

Replaces: NEW

Catalog No. PDS915SA---01

915SA

Summary of Contents for 915SA

Page 1: ...er S High quality corrosion resistant prepainted steel cabinet with hemmed edges for safety S Factory configured ready for upflow applications S Direct vent sealed combustion single pipe venting or ve...

Page 2: ...t 80 product a design with more than ten years of field proven performance and success These innovations paired with the continuation of a crimped no weld seam create an efficient robust design for th...

Page 3: ...x 11 11 x 11 Air Filtration System Field Supplied Filter Used for Certified Watt Data KGAWF1606UFR KGAWF1306UFR KGAWF1406UFR KGAWF1506UFR Electrical Data 30040 30060 42060 48080 60080 42100 60100 6012...

Page 4: ...0 5 ESP 040 40 000 BTU 060 60 000 BTU 080 80 000 BTU 100 100 000 BTU 120 120 000 BTU Not all familes have these models 140 140 000 BTU A12042 FURNACE COMPONENTS RATING PLATE NOT SHOWN LOCATED ON BLOW...

Page 5: ...igned system airflow and static pressure Use optional IAQ Device Duct Adapters as required 6 Available from Replacement Components group 7 Kit coming soon Expected availability 2Q2012 1 CSA requires t...

Page 6: ...2240 2145 2040 1920 1805 1675 1520 Yellow 2030 2010 1970 1925 1870 1805 1725 1630 1525 1400 Orange 1655 1660 1650 1635 1615 1575 1520 1450 1360 1270 Blue 1520 1520 1520 1520 1500 1475 1430 1360 1290 1...

Page 7: ...45 13 7 198 60 4 232 70 7 NA NA 60 000 27 8 2 127 38 7 222 67 7 250 76 2 NA 80 000 17 5 2 64 19 5 165 50 3 222 67 7 249 75 9 100 000 NA 22 6 7 104 31 7 223 68 0 250 76 2 120 000 NA NA 11 3 4 93 28 3 2...

Page 8: ...the Maximum Equivalent Vent Length MEVL from Table 1 or Table 3 minus the number of elbows multiplied by the deduction for each elbow in Table 2 Standard vent terminations and concentric vent termina...

Page 9: ...63 19 2 8001 to 9000 2438 to 2743 40 000 10 3 0 121 36 9 130 39 6 NA NA 60 000 7 2 1 82 25 0 152 46 3 168 51 2 NA 80 000 NA 35 10 7 111 33 8 148 45 1 156 47 5 100 000 NA NA 67 20 4 157 47 9 170 51 8...

Page 10: ...0 2 33 8 27 1 6 1 21 3 47 9 40 5 32 6 20 30 Ft 20 25 23 14 1 20 70 94 77 57 20 70 113 94 71 M 6 1 7 6 7 0 4 3 0 3 6 1 21 3 28 7 23 5 17 4 6 1 21 3 34 4 28 7 21 6 40 40 Ft 20 14 12 3 0 20 70 71 56 38 2...

Page 11: ...eat exchangers motors and controls 60 80 27 C 16 C SUPPLY AIR A10490 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS POSITION CLEARANCE Rear 0 0 mm Front Combustion air openings in furnace and in structur...

Page 12: ...Coil Assembly or Coil Box 22 1 8 562 0 19 482 6 23 3 4 603 3 20 3 8 517 5 1 The plenum should be constructed 1 4 in 6 mm smaller in width and depth than the plenum dimensions shown above Concentric V...

Page 13: ...AL BLOCK THREE WIRE HEATING ONLY FIVE WIRE NOTE 1 NOTE 2 FIELD SUPPLIED DISCONNECT CONDENSING UNIT TWO WIRE FURNACE C O N T R O L R G COM W C R G Y GND GND FIELD 24 V WIRING FIELD 115 208 230 460 V WI...

Page 14: ...14 DIMENSIONAL DRAWING A11612 915SA...

Page 15: ...have reusable type filters Filter shall be ______ in mm X ________ in mm An accessory highly efficient Media Filter is available as an option _____________ Media Filter Casing Casing shall be of 030...

Page 16: ...change at any time specifications or designs without notice and without incurring obligations E2012 Bryant Heating Cooling Systems D 7310 W Morris St D Indianapolis IN 46231 Printed in U S A Edition...

Reviews: