1

926TA

PREFERRED

t

TWO--STAGE

4--WAY MULTIPOISE, VARIABLE SPEED

CONDENSING GAS FURNACE, SERIES A

Product Data

A11264

The 926TA Multipoise Variable--Speed Condensing Gas Furnace

features the two--stage Preferred

t

Series System. The Perfect

Heat

R

technology two--stage gas valve is at the heart of the

comfort provided by this furnace, along with the variable--speed
ECM blower motor, and two--speed inducer motor. With an

Annual Fuel Utilization Efficiency (AFUE) up to 96.5%, the

Preferred

t

Series two--stage gas furnace provides exceptional

savings as well when compared to standard gas furnaces. This

Preferred

t

Series Gas Furnace also features 4--way multipoise

installation flexibility, and is available in eight model sizes. The

926TA can be vented for direct vent/two--pipe, ventilated

combustion air, or single--pipe applications.

All units meet

California Air Quality Management District emission requirements.

All sizes are design certified in Canada.

STANDARD FEATURES

S

All sizes meet ENERGY STAR

R

Version 4.0 criteria for gas

furnaces: 95+AFUE; AMACF electrical rating; 2% or less

cabinet airflow leakage.

S

Quiet operation. Compare for yourself at HVACpartners.com.

S

Ideal height 35” (889 mm) cabinet: short enough for taller coils,
but still allows enough room for service.

S

Silicon Nitride Perfect Light

Hot Surface Igniter.

S

SmartEvap

technology helps control humidity levels in the

home when used with a compatible humidity control system.

S

FanOn Plus

technology allows control of continuous fan speed

from a compatible thermostat.

S

4--way multipoise design for upflow, downflow or horizontal
installations, with unique vent elbow and optional through--
the--cabinet downflow venting capability.

S

Full--featured variable--speed blower motor, two--speed inducer
motor, and two--stage gas valve.

S

Self--diagnostics.

S

Adjustable blower speed for cooling, continuous fan, and
dehumidification.

S

Aluminized--steel primary heat exchanger.

S

Stainless--steel condensing secondary heat exchanger.

S

Propane convertible (See Accessory list).

S

Factory--configured ready for upflow applications.

S

Fully--insulated casing including blower section.

S

Convenient Air Purifier and Humidifier connections.

S

Direct--vent/sealed combustion, single--pipe venting or
ventilated combustion air.

S

Installation flexibility: sidewall or vertical vent.

S

Residential installations may be eligible for consumer financing
through the Retail Credit Program.

S

Certified to leak 2% or less of nominal air conditioning CFM
delivered when pressurized to 1--in. water column with all
present air inlets, air outlets, and condensate drain port(s) sealed.

C E RT I F I E D

Always Ask For

Use of the AHRI Certified 

TM

 Mark indicates a

manufacturer’s participation in the program.  For
verification of certification for individual products,
go to www.ahridirectory.org.

Summary of Contents for 926TA

Page 1: ...t Surface Igniter S SmartEvap technology helps control humidity levels in the home when used with a compatible humidity control system S FanOn Plus technology allows control of continuous fan speed fr...

Page 2: ...and continues Bryant s tradition of technology leadership and innovation in providing a reliable and durable product Full Featured Variable Speed Motors Our variable speed ECM Electronically Commutat...

Page 3: ...U 120 120 000 BTU 140 140 000 BTU Not all familes have these models 0 90 AFUE 2 92 AFUE 3 93 AFUE 5 95 AFUE 6 96 AFUE 7 97 AFUE Example of a Model Number A14367 FURNACE COMPONENTS RATING PLATE NOT SHO...

Page 4: ...peed Selections Variable PWM Blower Wheel Dia x Width in 11 x 7 11 x 8 11 x 7 11 x 8 11 x 8 11 x 10 11 x 10 11 x 11 Air Filtration System Optional Media Cabinet Field Supplied Filter Filter Used for C...

Page 5: ...as Orifice Kit 46 Nat Gas LH32DB208 D D D D D D D D Gas Orifice Kit 47 Nat Gas LH32DB078 D D D D D D D D Gas Orifice Kit 48 Nat Gas LH32DB076 D D D D D D D D Gas Orifice Kit 54 LP LH32DB203 D D D D D...

Page 6: ...ON OFF 770 725 685 640 600 560 515 480 See note 4 OFF ON ON 945 910 875 835 800 770 735 695 665 635 ON OFF OFF 1140 1105 1075 1040 1005 970 930 885 835 790 ON OFF ON 1250 1210 1165 1115 1065 1015 965...

Page 7: ...770 720 660 620 585 ON OFF OFF 1175 1140 1090 1060 1025 980 940 905 855 815 ON OFF ON 1325 1280 1245 1210 1180 1140 1105 1070 1025 990 ON ON OFF 1545 1515 1480 1445 1410 1380 1350 1315 1245 1175 ON O...

Page 8: ...1890 1750 1645 1550 Clg SW2 Maximum Clg Airflow 2 note 8 2375 2300 2205 2115 2010 1890 1750 1645 1550 Heating SW1 High Heat Airflow 3 note 8 2375 2300 2205 2115 2010 1890 1750 1645 1550 Low Heat Airfl...

Page 9: ...2 NA NA 60 000 23 7 0 119 36 3 210 64 0 235 71 6 NA 80 000 15 4 6 59 18 0 155 47 2 210 64 0 232 70 7 100 000 NA 19 5 8 98 29 9 211 64 3 236 71 9 120 000 NA NA 8 2 4 86 26 2 224 68 3 140 000 4 NA NA NA...

Page 10: ...ent Vent Length TEVL 112 ft Add all of the above lines Maximum Equivalent Vent Length MEVL 127 ft For 2 pipe from Table 1 Is TEVL less than MEVL YES Therefore 2 pipe may be used Example 2 A direct ven...

Page 11: ...9 8 63 19 2 8001 to 9000 2438 to 2743 40 000 10 3 0 121 36 9 130 39 6 NA NA 60 000 7 2 1 82 25 0 152 46 3 168 51 2 NA 80 000 NA 35 10 7 111 33 8 148 45 1 156 47 5 100 000 NA NA 67 20 4 157 47 9 170 51...

Page 12: ...44 8 0 20 Ft 20 0 32 0 30 0 22 0 11 0 20 0 70 0 104 0 87 0 67 0 20 0 70 0 124 0 104 0 82 0 M 6 1 9 8 9 1 6 7 3 4 6 1 21 3 31 7 26 5 20 4 6 1 21 3 37 8 31 7 25 0 20 30 Ft 20 0 17 0 14 0 6 0 0 0 20 0 7...

Page 13: ...PLY AIR A10490 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS POSITION CLEARANCE Rear 0 0 mm Front Combustion air openings in furnace and in structure 1 in 25 mm Required for service 24 in 610 mm All Sid...

Page 14: ...5 8 600 2 24 1 2 622 Furnace with or without Cased Coil Assembly or Coil Box 22 1 8 562 19 483 23 3 4 603 20 5 8 600 1 The plenum should be constructed 1 4 in 6 mm smaller in width and depth than the...

Page 15: ...FIELD SUPPLIED DISCONNECT AUXILIARY J BOX 24 V TERMINAL BLOCK THREE WIRE HEATING ONLY FIVE WIRE NOTE 1 NOTE 2 FIELD SUPPLIED DISCONNECT CONDENSING UNIT TWO WIRE FURNACE C O N T R O L R G COM W C R G Y...

Page 16: ...IMENSIONS IN INCH MM 22 2 7 8 7 8 22 2 POWER CONN AIR FLOW SEE NOTE 3 NOTES 1 Doors may vary by model 2 Minimum return air openings at furnace based on metal duct If flex duct is used see flex duct ma...

Page 17: ...Casing Casing shall be of 030 in thickness minimum pre painted steel Draft Inducer Motor Draft inducer motor shall be two speed PSC design Primary Heat Exchangers Primary heat exchangers shall be 3 P...

Page 18: ...e or change at any time specifications or designs without notice and without incurring obligations E2014 Bryant Heating Cooling Systems D 7310 W Morris St D Indianapolis IN 46231 Edition Date 09 14 Re...