48115
30- 60
(17 - 33)
Low
Blue
CFM
644
552
461
376
301
235
x
x
x
x
BHP
0.06
0.07
0.07
0.08
0.08
0.09
x
x
x
x
Gas Heat Rise (
°
F)
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
Gas Heat Rise (
°
C)
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
Med-Low
Pink
Alternate Cooling
Alternate Heating
CFM
1430
1386
1347
1302
1258
1208
1160
1114
1065
1014
BHP
0.26
0.27
0.28
0.29
0.30
0.30
0.32
0.33
0.34
0.35
Gas Heat Rise (
°
F)
60
NA
NA
NA
NA
NA
NA
NA
NA
NA
Gas Heat Rise (
°
C)
34
NA
NA
NA
NA
NA
NA
NA
NA
NA
Medium
Red
Cooling
Alternate Heating
CFM
1658
1622
1585
1549
1512
1476
1442
1402
1360
1322
BHP
0.39
0.40
0.41
0.42
0.44
0.45
0.46
0.47
0.48
0.49
Gas Heat Rise (
°
F)
52
53
55
56
57
59
60
NA
NA
NA
Gas Heat Rise (
°
C)
29
30
30
31
32
33
33
NA
NA
NA
Med-High
Orange
Heating
Alternate Cooling
CFM
1945
1913
1867
1829
1792
1758
1717
1688
1645
1603
BHP
0.58
0.59
0.61
0.63
0.64
0.65
0.67
0.68
0.69
0.71
Gas Heat Rise (
°
F)
44
45
46
47
48
49
50
51
53
54
Gas Heat Rise (
°
C)
25
25
26
26
27
27
28
28
29
30
High
Black
High Static Cooling Only
CFM
2201
2172
2138
2108
2074
2041
1970
1867
1764
1634
BHP
0.83
0.84
0.87
0.88
0.89
0.91
0.89
0.83
0.79
0.74
48130
35 - 65
(19 - 36)
Low
Blue
CFM
644
552
461
376
301
235
x
x
x
x
BHP
0.06
0.07
0.07
0.08
0.08
0.09
x
x
x
x
Gas Heat Rise (
°
F)
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
Gas Heat Rise (
°
C)
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
Med-Low
Pink
Alternate Cooling
CFM
1430
1386
1347
1302
1258
1208
1160
1114
1065
1014
BHP
0.26
0.27
0.28
0.29
0.30
0.30
0.32
0.33
0.34
0.35
Gas Heat Rise (
°
F)
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
Gas Heat Rise (
°
C)
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
Medium
Red
Cooling
Alternate Heating
CFM
1658
1622
1585
1549
1512
1476
1442
1402
1360
1322
BHP
0.39
0.40
0.41
0.42
0.44
0.45
0.46
0.47
0.48
0.49
Gas Heat Rise (
°
F)
58
59
61
62
63
65
NA
NA
NA
NA
Gas Heat Rise (
°
C)
32
33
34
34
35
36
NA
NA
NA
NA
Med-High
Orange
Heating
Alternate Cooling
CFM
1945
1913
1867
1829
1792
1758
1717
1688
1645
1603
BHP
0.58
0.59
0.61
0.63
0.64
0.65
0.67
0.68
0.69
0.71
Gas Heat Rise (
°
F)
49
50
51
52
54
55
56
57
58
60
Gas Heat Rise (
°
C)
27
28
29
29
30
30
31
32
32
33
High
Black
High Static Cooling Only
CFM
2201
2172
2138
2108
2074
2041
1970
1867
1764
1634
BHP
0.83
0.84
0.87
0.88
0.89
0.91
0.89
0.83
0.79
0.74
60090
35 - 65
(19 - 36)
Low
Blue
CFM
839
768
697
625
551
486
422
360
306
x
BHP
0.09
0.10
0.10
0.11
0.12
0.12
0.13
0.14
0.14
x
Gas Heat Rise (
°
F)
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
Gas Heat Rise (
°
C)
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
Med-Low
Pink
Heating
CFM
1403
1361
1320
1276
1236
1192
1145
1099
1054
1012
BHP
0.28
0.29
0.30
0.31
0.31
0.33
0.34
0.35
0.36
0.37
Gas Heat Rise (
°
F)
48
50
51
53
55
57
59
62
64
NA
Gas Heat Rise (
°
C)
27
28
28
29
30
32
33
34
36
NA
Medium
Red
Cooling
Alternate Heating
CFM
1822
1788
1757
1726
1690
1657
1623
1589
1553
1518
BHP
0.54
0.55
0.56
0.57
0.59
0.60
0.61
0.62
0.63
0.64
Gas Heat Rise (
°
F)
37
38
39
39
40
41
42
43
44
45
Gas Heat Rise (
°
C)
21
21
21
22
22
23
23
24
24
25
Med-High
Orange
Alternate Cooling
CFM
1982
1940
1900
1859
1816
1775
1739
1701
1655
1596
BHP
0.61
0.62
0.63
0.65
0.66
0.67
0.69
0.70
0.71
0.73
Gas Heat Rise (
°
F)
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
Gas Heat Rise (
°
C)
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
High
Black
High Static Cooling Only
CFM
2271
2241
2206
2171
2134
2080
1973
1857
1746
1596
BHP
0.90
0.91
0.93
0.95
0.96
0.95
0.90
0.84
0.78
0.73
Table 10 – Dry Coil Air Delivery
*
- Horizontal and Downflow Discharge Sizes 24-60 208/230VAC - 1 Phase (Continued)
Unit Size Heating Rise
°F (°C)
Motor Speed
Tap
Allowable
Functions
ESP (in. W.C.)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1