background image

3

sorbed from the outside air. So, to maintain energy--efficient opera-
tion, your unit has an automatic defrost mode.
The defrost mode starts at a preset time interval of 60 minutes, al-

though, it may be reset to 30, 90 or 120 minutes. Defrost will start

at the preset time only if the ice is sufficient to interfere with normal
heating operation.
After the ice is melted from the coil, or after a maximum of 10 min-

utes in defrost mode, the unit automatically switches back to normal
heating operation.
Do not be alarmed if steam or fog appears at the outdoor unit during
defrost mode. Water vapor from the melting ice may condense into

a mist in the cold outside air.
During certain weather conditions such as heavy snow and freezing
rain it is not uncommon for ice to build up on the unit grille. This is

normal for these weather conditions. Do not attempt to remove the

ice from the unit grille. This condition will not affect the proper
function of the unit and will clear within a few days.

Emergency Heating Mode

In the event of primary unit heat failure, the emergency heat mode
allows your supplemental heating source to keep your home or of-

fice warm until your unit can be serviced. Contact your dealer in the

event of primary unit heat failure.

MAINTENANCE AND SERVICE

This section discusses maintenance that should be performed by
your dealer and care you, as the owner, may wish to handle for your

new unit.

Routine Maintenance

All routine maintenance should be handled by skilled, experienced
personnel. Your dealer can help you establish a standard procedure.
To assure proper functioning of the unit, flow of condenser air must

not be obstructed from reaching the unit. Clearance from the top of
the unit is 48 in. (1219 mm). Clearance of at least 36 in. (914 mm)

is required on sides except the power entry side (42 in. clearance)

(1067 mm) and the duct side (12 in. minimum clearance) (305 mm).

Maintenance and Care for the Equipment Owner

Before proceeding with those things you might want to maintain

yourself, please carefully consider the following:

FIRE, EXPLOSION, ELECTRICAL SHOCK, CUT

HAZARD

Failure to follow this warning could result in personal injury,

death or property damage.

1. TURN OFF ELECTRICAL POWER TO YOUR UNIT

BEFORE

SERVICING

OR

PERFORMING

MAINTENANCE AND INSTALL A LOCK--OUT TAG.

2. When removing access panels or performing maintenance

functions inside your unit, be aware of sharp sheet metal

parts and screws. Although special care is taken to reduce
sharp edges to a minimum, be extremely careful when

handling parts or reaching into the unit.

!

WARNING

Air Filters
The air filter(s) should be checked every 3 or 4 weeks and changed

or cleaned whenever it becomes dirty. Dirty filters produce exces-

sive stress on the blower motor and can cause the motor to overheat
and shut down.
This unit must have an air filter in place before it can be operated.

These filters should be located in at least one of two places. In many

applications, the installer will provide return air filter grilles
mounted on the wall or ceiling of the conditioned structure. In the

instance of filter grilles, the filters can simply be removed from the
grille and replaced.
The other typical application is an accessory filter rack installed in-

side the unit itself. The following information is given to assist in
changing filters used in these internal filter racks.
Table 1 indicates the correct indoor filter size for your unit. Refer

to Fig. 3 to access filters installed in the accessory filter rack. If using

an Accessory Filter Rack, refer to the Installation Instructions pro-
vided with it for correct filter sizes and quantities.

Table 1—Air Filters Located Inside Unit

(For Replacement Purposes)

Unit Size

Filter Size in. (mm)

A24

20x20x1 (508x508x25)

A30

20x24x1 (508x610x25)

A36---A42

24x30x1 (610x762x25)

A48---A60

24x36x1 (610x914x25)

To replace or inspect filters in accessory filter rack:

1. Remove the filter access panel (See Fig. 3) using a 5/16--in.

nut driver.

2. Remove the filter(s) by pulling it out of the unit. If the filter(s)

is dirty, clean or replace with a new one.

When installing the new filter(s), note the direction of the airflow ar-

rows on the filter frame.
If you have difficulty locating your air filter(s) or have questions

concerning proper filter maintenance, contact your dealer for in-
structions. When replacing filters, always use the same size and type

of filter that was supplied originally by the installer.

Access Panels

Filter Access Panel

For Accessory Filter Rack

A09044

Fig. 3 -- Accessory Filter Rack Access Panel

FIRE AND UNIT OPERATION HAZARD

Failure to follow this warning could result in personal injury,

death or property damage.
Never operate your unit without filters in place. An

accumulation of dust and lint on internal parts of your unit can

cause loss of efficiency.

!

WARNING

Fans and Fan Motor
Periodically check the condition of fan wheels and housings and

fan--motor shaft bearings. Contact your dealer for the required annu-

al maintenance.
Indoor and Outdoor Coils
Cleaning of the coils should only be done by qualified service per-
sonnel. Contact your dealer for the required annual maintenance.

Summary of Contents for LEGACY 604D

Page 1: ...e UNIT INFORMATION Model _____________________________________ Serial ______________________________________ ACCESSORIES List type and model _____________________________________________ _____________________________________________ _____________________________________________ INSTALLATION INFORMATION Date Installed ________________________________ DEALERSHIP CONTACT INFORMATION Company Name_____...

Page 2: ...ution may result in personal injury Sheet metal parts mayhave sharpedges or burrs Use careand wear appropriate protective clothing safety glasses and gloves when handling parts and servicing furnaces CAUTION OPERATING YOUR UNIT The operation of your heat pump system is controlled by the indoor thermostat You simply adjust the thermostat and itmaintains thein door temperature at the level you selec...

Page 3: ... is taken to reduce sharp edges to a minimum be extremely careful when handling parts or reaching into the unit WARNING Air Filters The air filter s should be checked every 3 or 4 weeks and changed or cleaned whenever it becomes dirty Dirty filters produce exces sive stress on the blower motor and can cause the motor to overheat and shut down This unit must have an air filter in place before it ca...

Page 4: ...n of the unit casing for signs of deterioration 7 Inspection of all electrical wiring and components to assure proper connection 8 Inspection for leaks in the refrigerant circuit Pressure and temperature check to determine appropriate refrigerant charge 9 Operational check of the unit to determine working conditions Repairoradjustmentshouldbe madeat thistime Your servicing dealer may offer an econ...

Reviews: