background image

4

Condensate Drain
The drain pan and condensate drain line should be checked and

cleaned at the same time the cooling coils are checked by your deal-
er.
Compressor
All compressors are factory shipped with a normal charge of the cor-
rect type and quantity of refrigeration grade oil. A compressor

should rarely require additional oil.
Condenser Fan

PERSONAL INJURY AND UNIT DAMAGE HAZARD

Failure to follow this warning could result in personal injury,

death or property damage.
Do not poke sticks, screwdrivers, or any other object into

revolving fan blades.

!

WARNING

The fan must be kept free of all obstructions to ensure proper cool-
ing. Contact your dealer for any required service.
Electrical Controls and Wiring
Electrical controls are difficult to check without proper instrumenta-

tion. If there are any discrepancies in the operating cycle, contact

your local dealer and request service.
Refrigerant Circuit
The refrigerant circuit is difficult to check for leaks without the prop-
er equipment. If inadequate cooling is suspected, contact your local

dealer for service.

EXPLOSION,

BURN

AND

ENVIRONMENTAL

HAZARD

Failure to follow this warning could result in personal injury,

death or property damage.
System under pressure. Relieve pressure and recover all

refrigerant before system repair or final unit disposal. Use all

service ports and open all flow--control devices, including

solenoid valves.

!

WARNING

Unit Panels
After performing any maintenance or service on the unit, be sure all
panels are fastened securely in place to prevent rain from entering

unit cabinet and to prevent disruption of the correct unit airflow pat-

tern.

Regular Dealer Maintenance

In addition to the type of routine maintenance you might be willing
to perform, your unit should be inspected regularly by a properly

trained service technician. An inspection (preferably each year, but
at least every other year) should include the following:

1. Inspection and, if required, cleaning of the outdoor and

indoor coils.

2. Inspection and, if required, cleaning of the indoor coil drain

pan.

3. Inspection and cleaning of blower wheel housing and motor.
4. Inspection of all supply and return air ducts for leaks,

obstructions, and insulation integrity. Any problems found

should be resolved at this time.

5. Inspection of the unit base to ensure that no cracks, gaps, etc.,

exist which may cause a hazardous condition.

6. Inspection of the unit casing for signs of deterioration.
7. Inspection of all electrical wiring and components to assure

proper connection.

8. Inspection for leaks in the refrigerant circuit. Pressure and

temperature check to determine appropriate refrigerant

charge.

9. Operational check of the unit to determine working

conditions. Repair or adjustment should be made at this time.

Your servicing dealer may offer an economical service contract that

covers seasonal inspections. Ask for further details.
Complete service instructions can be found in the unit Installation,

Start--up and Service Instructions.

Warranty Certificate

Your unit has a limited warranty. Be sure to read the warranty care-

fully to determine the coverage for your unit.

Before you call for service...

...check for several easily solved problems.

If insufficient heating or cooling is suspected:

( ) Check for sufficient airflow. Check the air filter for dirt. Check

for blocked return or supply air grilles. Be sure they are open and un-
obstructed. If these checks do not reveal the cause, call your servic-

ing dealer.

If your unit is not operating at all, check the following list for

easy solutions:

( ) Check to be sure that your thermostat temperature selector is set

below the indoor temperature during the cooling season or above
the indoor temperature during heating season. Be sure the SYSTEM

switch or MODE control is in the COOL or HEAT and not OFF.
( ) If your unit still fails to operate, call your servicing dealer for

troubleshooting and repairs. Specify the model and serial numbers

of your unit. (Record them in this manual in the space provided.) If
the dealer knows exactly which unit you have, he may be able to of-

fer suggestions over the phone, or save valuable time through
knowledgeable preparation for the service call.

In Case of Trouble

If you perform the steps above and unit performance is still unsatis-
factory, shut off the unit and call your dealer.

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Copyright 2009 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indianapolis, IN 46231

Heating & Cooling Systems

TO OBTAIN INFORMATION ON PARTS: Consult your installing dealer or classified section of your local telephone directory under the

“Heating Equipment” or “Air Conditioning Contractors & Systems” heading for dealer listing by brand name.

Have available the Model No., Series Letter, & Serial No. of your equipment to ensure correct replacement part.

Printed in the U.S.A.

Replaces: OM604D--- 01 AND OM607C--- 01

Catalog No:OM604D---607C---01

Edition Date: 03/09

Summary of Contents for LEGACY 604D

Page 1: ...e UNIT INFORMATION Model _____________________________________ Serial ______________________________________ ACCESSORIES List type and model _____________________________________________ _____________________________________________ _____________________________________________ INSTALLATION INFORMATION Date Installed ________________________________ DEALERSHIP CONTACT INFORMATION Company Name_____...

Page 2: ...ution may result in personal injury Sheet metal parts mayhave sharpedges or burrs Use careand wear appropriate protective clothing safety glasses and gloves when handling parts and servicing furnaces CAUTION OPERATING YOUR UNIT The operation of your heat pump system is controlled by the indoor thermostat You simply adjust the thermostat and itmaintains thein door temperature at the level you selec...

Page 3: ... is taken to reduce sharp edges to a minimum be extremely careful when handling parts or reaching into the unit WARNING Air Filters The air filter s should be checked every 3 or 4 weeks and changed or cleaned whenever it becomes dirty Dirty filters produce exces sive stress on the blower motor and can cause the motor to overheat and shut down This unit must have an air filter in place before it ca...

Page 4: ...n of the unit casing for signs of deterioration 7 Inspection of all electrical wiring and components to assure proper connection 8 Inspection for leaks in the refrigerant circuit Pressure and temperature check to determine appropriate refrigerant charge 9 Operational check of the unit to determine working conditions Repairoradjustmentshouldbe madeat thistime Your servicing dealer may offer an econ...