11/25
3.1.4 Fusing
The
BSG
is capable of producing high amperages. As with all electrical
installations, you must protect each of your turbines with a properly sized
fuse or circuit breaker. The
BSG
should be wired with an appropriately sized
“slow-blow” type fuse between itself and the batteries. If a controller is used,
the fuse should be placed between the switch and the batteries.
3.1.5 Charge Controller
In the package, you will also find a solar &wind hybrid controller which is shown in the
following picture, please note, this charger only use for Max.400W wind generator:
Please read this Manual carefully before using this equipment.
3.1.5.1 Security
In the design of this product has been fully taken into account the personal and
property safety, but the un-correct using way may lead to the occurrence of
failures, even lead to burn this charging controller , in order to guarantee the
safety of you, please follow with the following rules when you are using this
equipment:
·Need the guidance of the professional or contact with the dealer for the installing way when Installing the
charger controller.
·Do not spill any liquid into the charger controller, please don’t use the wet cloth to brush the shell of it.
·Do not let children or the lack of independent people to use this product
·This product should not be placed in the electric heater and other sources of heat use, and try to avoid
direct sunlight
·Please check carefully before connecting to the solar panels, batteries and the load, their rated voltage
should be the same, it should be 12V or (24V).
·Please pay high attention and make sure to connect to the right way of the "+","-" poles of the solar
panels, batteries and load.
·The diameter of the electrical wire should burden to the current..
·The current of the solar panels and load must be less than the rated current of the charger controller.
·The connections must be firmly and ensure good contact.
·Prohibit short circuit for the connected "+,-"poles of the batteries.
3.1.5.2 Characteristics
B L A C K 2008 charge controller is battery power, constant voltage control mode,
the 12 V, 24V batteries Universal. According to the battery voltage level, adjusting
the charge current size, decide whether to load electricity or not, and has the
following properties:
.12V, 24V battery control system automatically switches
.Brake show for the wind generator
.12V, 24V switch Show
·Keep a full battery
·Prevent excessive battery charge
·Showing excessive battery discharge
·prevent the battery charging solar panels reversely at night