12/25
·Reverse connection for the battery protection
·Reverse connection for the solar panels protection.
·When the charge controller start up, it can set automatically the stop charging voltage, load
downtime voltage, load restoration voltage according to the battery voltage, these parameters are
the Windows default at the ambient temperature at 25
℃
.
·The controller will automatically charge voltage temperature compensation According to the
changes of the environmental temperature.
·Users can stop filling according to their own needs.
·To prevent excessive battery discharge, the charge controller control minimum load downtime
voltage automatically, it should be not less than 10 V (for 12 V batteries) or 20 V (for 24 V batteries).
3.1.5.3 System wire connection
As shown as the following picture
figure 3
·Please connect the “+”
、
“-”pole of batteries firmly to the end of output “+”
、
“-”poles of the
charge controller.
·Connect the "+","-"poles of the solar panel to the solar "+","-"poles of charge
controller.
·Connect the three phrases of the wind generator to the wind generator as shown in the
above picture.
Attention please!
·Please make sure in connection of the “+”
、
“-”poles of the solar panels, batteries and
load.
·According to the current, please select suitable diameter for electric wire, and must not
be too small, recommended diameter
≥
6 sq mm
3.1.5.4 Technic parameter
Style no
:
B L A C K 2008