9
AC Power Connections and Control Settings
Before connecting the MSR-602 II to the AC power source, check
that the voltage selector switch located on the rear panel is cor-
rectly set. If a change is necessary, ensure that the mains fuse is
also changed for one of the correct rating. Before connecting the
DC power leads, check that the system ground switch on the rear
panel is also correctly set to ‘earthed’.
The power cord attached to this unit carries the following informa-
tion label.
WARNING:THIS APPLIANCE MUST BE EARTHED
IMPORTANT:
The wires in this mains lead are colour coded in
accordance with the following code.
Green and yellow :
Earth
Blue
:
Neutral
Brown
:
Live
As the colours of the wires in the mains lead of this appliance may
not correspond with the coloured markings identifying the terminals
in your plug, proceed as follows:
The wire which is coloured green-and-yellow must be connected to
the terminal in the plug which is marked with the letter ‘E’ or by the
earth symbol which is ‘ ‘, or coloured green or green-and-yellow.
The wire which is coloured blue must be connected to the terminal
which is marked with the letter ‘N’ or coloured black.
The wire which is coloured brown must be connected to the terminal
which marked with the letter ‘L’ or coloured red.
Those units that are supplied to the North American market will
have an integral moulded 3 pin connector which is provided to
satisfy required safety standards.
3.1 AC Power
Connections and
Control Settings
T2AL250V
T3.15AL250V
Fig. 3 MSR-602 II
Voltage Switch and
Mains Fuse
Summary of Contents for MSR-600 II Series
Page 36: ...3 4 MSR 600 II Series USER NOTES...