background image

 

Page 

2

 of 

7

 

Thanks for choosing BT Lab Systems’ Rocking Shaker. This operation manual describes the function and 
operation of the instrument.  In order to use the instrument properly, please read this manual carefully. 

Please check the instrument with the packing list when you first open the packing case.   If items do not 
match the packing list, please contact BT Lab Systems. 

IMPORTANT SAFETY INFORMATION  

Users should understand how to use the instrument properly before operating it.  Please read this 
operation manual carefully before using the instrument. 

The operation, maintenance and repair of the instrument should comply with the basic guidelines and 
warning below.  Ignoring these instructions will affect the life of the Instrument and safety precautions. 

 

This product is an indoor Instrument which conforms to Standard B style- I type- GB9706.1. 

 

Before operation, read the manual carefully. These units are designed for using in laboratory 
environments by persons knowledgeable in safe laboratory practices. 

 

The operator should never open or repair the instrument.  Opening or repairing the instrument will 
void the guarantee and can cause accidents. 

 

The power plug is designed to safeguard against an electric shock. The 3-pin plug supplied with 
BT907 Rocking Shaker’s power cable is a safety device that should be matched with a suitable 
grounded socket. 

 

The instrument should be used in an area with low temperature, little dust, no water, no sunshine 
or hard light and with good air circulation.  Do not use where there is corrosive gas or a strong 
magnetic field.  Keep far away from central heating, camp stove and other hot sources.  Do not put 
the instrument in a wet and dusty area. The vent on the instrument is designed for aeration.  Do not 
wall up or cover the vent.  

 

Power off when not in use.  If the instrument will not be used for a long period, unplug, and cover 
with a piece of cloth to protect it from dust. 

 

In case of the following, unplug the instrument at once and contact BT Lab Systems. 

o

 

The instrument comes into contact with liquid 

o

 

The instrument gets soaked or burned 

o

 

The instrument emits an abnormal sound or smell 

o

 

The instrument is dropped or the outer shell damaged 

o

 

The instrument functions abnormally. 

MAINTENANCE 

The instrument and the accessories should be cleaned with a cloth dampened by alcohol. 
If there are smudges on the instrument, clean it with a dry cloth. 
 

 

Summary of Contents for BT907

Page 1: ...A Geno Technology Inc USA brand name 1 800 628 7730 1 314 991 6034 info BTLabSystems com Rocking Shaker Cat No BT907 BT925 ...

Page 2: ...trument will void the guarantee and can cause accidents The power plug is designed to safeguard against an electric shock The 3 pin plug supplied with BT907 Rocking Shaker s power cable is a safety device that should be matched with a suitable grounded socket The instrument should be used in an area with low temperature little dust no water no sunshine or hard light and with good air circulation D...

Page 3: ...ne transfer KEY FEATURES Platform made of stainless steel and natural rubber alkali resistant easy to clean and prevents spilling Speed display shows current speed and time display counts down time The instrument uses articulated rotation that is stable and long wearing suitable for prolonged use Compact design takes up very little space Brushless DC motor maintenance free NORMAL OPERATING CONDITI...

Page 4: ... slip mat EQUIPMENT OVERVIEW This chapter describes the instrument s mechanical structure the keyboard and functions of each key as well as operation Please learn this chapter before the instrument is operated for the first time Platform Keyboard ...

Page 5: ...or of time key to adust the timing value It displays last setting time Continously pressing leads the value increse or decrease in X10 speed Stop Start 1 Press the start stop key to start or stop the program 2 Press start stop to run the program after speed and timing are set When the time is up the instrument stops running and sounds an alert 3 Press stop start to stop the program 4 When the prog...

Page 6: ...ng this warranty period BT Lab Systems will repair or replace the defective parts at its discretion without charge The following defects however are specifically excluded 1 Defects caused by improper operation 2 Repair or modification done by anyone other than BT Lab Systems or an authorized agent 3 Damage caused by substituting alternative parts 4 Use of fittings or spare parts supplied by anyone...

Page 7: ...r s warranty 2 Void the safety and EMC certification 3 Create a potential safety hazard BT Lab Systems is not responsible for any injury or damage caused by the use of this instrument for purposes other than those for which it is intended or by modifications of the instrument not performed by BT Lab Systems or an authorized agent TECHNICAL SUPPORT BT Lab Systems offers technical support for all of...

Reviews: