PS
S5.5
5710
000
Version no
T-code
F-code
Section
C-code
EV100 Handset Operation
238
Service Manual
1997-09-15
6.13. Function 17
Card Type Selection (Push CONT and 2)
This function allows for the selection of the card type used for
your vehicle's application. The table below shows the setting
to select card application type depending on which control
card is used.
Settings for these functions should be made in between the
values shown.
EV100
Standar
Speed
Function
with F
Limit
Regen/FW
STD C/L
0 to 4
20 to 24
40 to 44
High C/L
5 to 9
25 to 29
45 to 49
STD C/L
(Auto plug)
10 to 14
30 to 34
50 to 54
High C/L
(Auto plug)
15 to 19
35 to 39
55 to 59
EV200
Standar
Speed
Function
with F
Limit
Regen/FW
STD C/L
64 to 68
84 to 88
104 to 108
STD C/L
(Auto plug)
74 to 78
94 to 98
114 to 118
These settings must be
changed
by
authorized personnel
only, following
instructions supplied by the manufacturer.
Card type selection must be made within
the capabilities of the SCR control panel
used and
the supporting electro-
mechanical devices. Failure to comply with
proper application standards could result
in mis-operation or damage to the control
and/or motors.
WARNING
Return
Summary of Contents for OE35
Page 2: ...Return ...
Page 10: ... BT Products 8 Table of Contents Return ...
Page 331: ...Return ...