Service Manual
1997-07-15
TABLE # 2
Primary Sources of Unsatisfactory Brush
Performance
Preparation and Care of Machine
1.
Poor preparation of commutator surface
2.
High mica
3.
Feather-edge mica
4.
Bar edges not chamfered after undercutting
5.
Need for periodic cleaning
6.
Clogged ventilating ducts
Machine Adjustment
7.
Brushes in wrong position
8.
Unequal brush spacing
9.
Poor alignment of brush holders
10. Incorrect brush angle
11. Incorrect spring tension
12. Interpoles improperly adjusted
13. Series field improperly adjusted
Mechanical Fault in Machine
14. Brushes tight in holders
15. Brushes too loose in holders
16. Brush holders loose at mounting
17. Commutator loose
18. Loose pole pieces or pole-face shoes
19. Loose or worn bearings
20. Unequal air gaps
21. Unequal pole spacing
22. Dynamic unbalance
23. Variable angular velocity
24. Commutator too small
Electrical Fault in Machine
25. Open or high resistance connection at commutator
26. Poor connection at shunt terminal
27. Short circuit in field or armature winding
28. Ground in field or armature winding
29. Reversed polarity on main pole or interpole