4 – 6
Repair manual
SWE100, 120, 120L, 120S, 140, 140L, 200D
© BT
Installation
Setting the parameters
T code
Valid from serial no.
Date
Order no.
841×842×843
6061850-
2012-08-30
258946-120
4.4.1 Adjusting the parameters for collision
sensor (option)
This parameters for collision sensitivity must be adjusted on truck
installation.
If a collision sensor is installed on the CAN bus, this registers when the
truck knocks against something. If a knock exceeds a certain level,
indicated by parameters 105 and 106, this is calculated as a collision
and the truck's speed is reduced to creep speed, a signal sounds and
error code 8.001 is shown on the display.
Information about the collision is stored in the truck's internal memory.
The last ten registered collisions can be read directly on the display and
the driver's identity can also be read via the PIN code. Other
information is received via TruckCom where the collision levels and
times can also be seen.
Collision sensor parameters 105, 106 och 111
See the table below for information about the values that can be stated:
Note!
If you set the parameter value for the collision sensor at 0 (zero) this
means that the collision sensor and the log function are turned off.
Service parameters
Parameter
Name/unit
Min/
Max
Incr
eme
nt
Std
Description
105
Collision
sensor
X level
0/100
1
0
States the degree
of sensitivity for
what should be
interpreted as a
collision for a
shock to the side.
106
Collision
sensor
Y level
0/100
1
0
States the degree
of sensitivity for
what should be
interpreted as a
collision for a
shock to the front
or back.
111
Resetting
following a
collision
0/1
1
0
0 = Special
pincode required
for resetting after a
collision.
1 = The truck can
be reset using all
activated pincodes.