Instructions for disposal
Pressure vessels
© BT
Repair manual
SWE100, 120, 120L, 120S, 140, 140L, 200D
27 – 3
Order no..
Date
Valid from serial no.
T code
258946-120
2012-08-30
6061850-
841×842×843
27.3 Pressure vessels
Pressure vessels sent for recycling/destruction must have been
depressurised beforehand and, if possible, opened.
Examples of existing pressure vessels are gas struts and accumulators
used in hydraulic systems.
27.3.1 Gas struts
WARNING!
Gas struts have extremely high internal pressure. To prevent injury,
always follow the instructions of the manufacturer.
Wear safety goggles when disassembling struts.
To allow the gas to escape, only open and disassemble gas struts as
prescribed by the manufacturer. An example of how to perform this is
given for "Stabilus Lift-O-Mat/Inter-stop":
1: Drill or cut a hole in the cylinders, approximately 20 mm from the
bottom.
2: Drill or cut a hole in the recess at the piston rod end.
ca 20 mm
1
2
https://www.besttruckmanuals.com/