Functions and parameters
Parameters
© BT
Repair manual
SWE100, 120, 120L, 120S, 140, 140L, 200D
6 – 19
Order no..
Date
Valid from serial no.
T code
258946-120
2012-08-30
6061850-
841×842×843
* Matrix for hardware/software compatibility
See the matrix below for the correct setting of factory parameter 1024.
The setting depends on what version of transistor regulator the truck is
fitted with.
•
Value 0 = 1.5 kHz (default value)
•
Value 1 = 8 kHz
1023
Controls for
hydraulic functions
1/4
1
1
1= The rear lifting and lowering
control is connected to the second
hydraulic function, while the front
control is connected to the first
hydraulic function.
2 = Rear lift and lowering control
connected to the first hydraulic
function and forward control
connected to second hydraulic
function.
3 = Both lifting and lowering
controls are connected to the first
hydraulic function. There are no
other hydraulic functions.
4= The analogue lifting and
lowering control is connected to the
first hydraulic function, while the
front control is connected to the
second hydraulic function.
1024
Brake configuration
* see below
0/1
1
0
0= 1.5KHz braking frequency
1= 8KHz braking frequency
1101
Battery charger, on-
board
0/1
1
0
0 = No battery charger installed
1 = Battery charger installed
Transistor regulator
Factory parameter 1024
Value = 0
Value = 1
243428/-001/-002
246889/-001/-002
246890/-001/-002
OK
Not permitted
7513528-001/-newer
7513526-001/-newer
7513527-001/-newer
Not
recommended
OK
Param
eter
Designation/
unit
Min./
Max.
Incr
eme
nt
Def
aul
t
Description
https://www.besttruckmanuals.com/