Troubleshooting
Error codes
© BT
Repair manual
SWE100, 120, 120L, 120S, 140, 140L, 200D
7 – 17
Order no..
Date
Valid from serial no.
T code
258946-120
2012-08-30
6061850-
841×842×843
3.562
The transistor regulator interrupts all
functions
The transistor regulator output to the
parking brake is open.
Check:
•
connections and wiring harness
•
parking brake.
3.563
Transistor regulator stops all functions.
The transistor regulator coil circuit to
the parking brake is open.
Check:
•
connections and wiring harness
•
parking brake.
3.580
Transistor regulator stops all functions.
The main contactor is closed.
Check:
•
connections and wiring harness
•
the main contactor.
3.581
Transistor regulator stops all functions.
Main contactor open.
Check:
•
connections and wiring harness
•
the main contactor.
•
the main fuse [F1]
3.582
Transistor regulator stops all functions.
The transistor regulator's output for
power supply has the wrong voltage.
Check:
•
connections and wiring harness
•
main contactor
•
lowering valve
•
brake
•
pump contactor.
Internal transistor regulator error.
Change transistor regulator.
3.583
Transistor regulator stops all functions.
Internal transistor regulator voltage
supply is not switched on.
Internal transistor regulator error.
Change transistor regulator.
Code
Event
Possible cause
Action