RATING PLATE
The rating label on the side of the unit provides the following details:
A – model
B – serial number
C – date of manufacture
D – mains voltage
E – input current
F – fuse rating
G – output voltage
H – output current
I – charging curve
L – range of battery sizes possible
NOTE:
The rating plate stipulates the initial setting of DC voltage (G) and current (H). The setting of
your particular unit may be different. Refer to the programmed setting shown on the front of the charger.
OTHER TECHNICAL DATA
Storage Temperature Range: - 40 to +50 degrees Celcius
Relative Humidity Range:
0 – 80%
Operating Temperature Range: -10 to +45 degrees Celcius
REPAIRS
Repairs must only be carried out by qualified personel.
Use only original equipment manufacturers (OEM) parts for repairs.
ELECTRICAL FEATURES
1. System input 115V/240V 50-60Hz
2. Charging parameters insensitive to
10% system voltage variations.
4. Efficiency > 90%.
5. Output ripple at max load below 150mV.
6. Accuracy of power and voltage measurements 1%.
ELECTROMAGNETIC COMPATIBILITY
The tests of electromagnetic compatibility (
EMC
) on these devices were carried out in compliance
with the
CEI EN55014-1+A2(04/98-06/99) and
CEI EN 55014-2(10/98) STANDARD norms, with
the test instructions and conditions as requested by the norms
.
NORM
RESULT
EN 55014-1+A2
COMPLIANT
EN 55014-1
COMPLIANT
EN 61000– 3-2
COMPLIANT
EN 61000– 3-3
COMPLIANT
EN 61000– 4-2
COMPLIANT
EN 61000– 4-4
COMPLIANT
EN 61000– 4-5
COMPLIANT
EN 61000– 4-6
COMPLIANT
EN 61000– 4-11
COMPLIANT
As to the immunity the devices are classified as Category II.
ELECTRICAL APPROVALS
The CBHF2-PFC charger is cULus listed.
AC Cord 6 feet long
DC Cord 3 feet long