2
Front and rear view
5
5
*
This device does not support standard POE power supplies, but only POE power supplies identified with 375002.
Connect the cat5/5e/6 FTP or cat5/5e/6 UTP cable with ferrite supplied to the connector.
Hereby, BTicino S.p.A., declares that the radio equipment type Indoor unit with camera 7" - 373002 / Indoor unit 7" - 373004 is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address: www.bticino.it/red
Read carefully before use and keep for future reference
Touching the units with wet hands is forbidden
Using liquid cleaners or aerosols is forbidden
Blocking the ventilation openings is forbidden
Modifying the devices is forbidden
Removing protective parts from the devices is forbidden
Installing the units near liquids and powders is forbidden
Installing the units near heat sources is forbidden
Installing the units near harmful gases, metal dusts or similar is forbidden
Fastening the units on unsuitable surfaces is forbidden
Danger of electrical shock
Risk of devices falling because the surface on which they are installed collapses or inappropriate installation
Switch the power supply OFF before any work on the system
Caution: Installation, configuration, starting-up and maintenance must be performed exclusively by
qualified personnel.
Check that the wall installation has been carried out correctly
Lay out the wires respecting the standards in force
Connect the power supply wires as indicated
Use only the items indicated in the technical specifications for any system expansions
Remote operation may cause damage to people or property.
Warnings and consumer rights
Configuration
The device must be configured by software. For software download, installation device documentation and for any
other information, refer to the website.
www.homesystems-legrandgroup.com
1. Microphone
2. Camera(only 373002)
3. Display 7" (touch screen)
4. Notification LED
LED flashing= notification of a message
5. Loudspeaker
6. SOS push button
7. Fixing magnets for bracket
8. USB Connector (not used)
9. Not used
10. Additional power supply clamps
(not polarized)
11. RJ45 Connector *
12. Connection clamp
Technical data
Voltage
24 Vdc
Maximum consumption
0.55 A
Max. cable section for clamps
0.8 mm²
Operating temperature
(- 10) – (+ 55)°C
IP degree of protection
IP30
Maximum relative humidity
93%
8
9
10
7
7
11
12
2
4
1
3
6
All contacts must be connected to GND and the corresponding dedicated input.
The functions and wiring mode of the inputs are set by default as shown in the table and diagram, they can be customized using the software and/or straight from the device.
Tamper and Doorbell input are not customizable and SOS-GND is disable by default.
560 Ω
560 Ω
GND
contacts from
F1 ÷ F8
GND
SOS
DoorBell
Tamper
Connection clamps
SOS – GND
Additional SOS call
F1 – GND
Infrared
DoorBell – GND
Door bell call
F2 – GND
Magnetic contact
Tamper – GND
Tamper
F3 – GND
Smoke sensor
GND
future use
F4 –GND
Gas sensor
485-A1
F5 – GND
Water sensor
485-B1
F6 – GND
Magnetic contact
GND
F7 – GND
Magnetic contact
485-A2
F8 – GND
SOS
485-B2
+12V – GND
12Vdc, maximum 150 mA
sensor power supply