background image

Entrance Panel keyboard 4.3"

User and installation manual

53

52

Summary of Contents for 374001/03

Page 1: ...Entrance Panel keyboard 4 3 374001 03 User and installation manual www bticino com RA00189AA 01 22 PC ...

Page 2: ...Entrance Panel keyboard 4 3 User and installation manual ...

Page 3: ... bandwidth demand 19 Available functions 20 Lift control 1 Lift control 1 riser 1 entrance panel 21 Lift control 2 Lift control multi riser 1 entrance panel 22 Lift control 3 Lift control 1 riser multi entrance panel 23 Use of the device 24 Introduction 24 Use of the device 25 Home page 25 Functions 26 Call a IU 26 Answering machine 28 Messages and advertising 29 Call a GS 30 Accesses 31 Access us...

Page 4: ...or splashes is forbidden Installing the units near heat cold sources or hot cold air emission points is forbidden Installing the units near heat cold sources is forbidden Installing the units near harmful gases and powders is forbidden Fastening the units on unsuitable surfaces is forbidden Danger of electrical shock Risk of devices falling because the surface on which they are installed collapses...

Page 5: ...CE DEVICE DEVICE Floor 4 Apartment 1 Apartment 2 Apartment 1 Apartment 2 DEVICE DEVICE DEVICE DEVICE Floor 3 Apartment 1 Apartment 2 Apartment 1 Apartment 2 DEVICE DEVICE DEVICE DEVICE Floor 2 Apartment 1 Apartment 2 Apartment 1 Apartment 2 DEVICE DEVICE DEVICE DEVICE Floor 1 Apartment 1 Apartment 2 Apartment 1 Apartment 2 DEVICE DEVICE DEVICE DEVICE RISER 1 RISER 2 EP Building BUILDING 2 Floor 5 ...

Page 6: ...ach call sector Area Building Riser Floor Apartment must be set Example I have to call an apartment inside building 2 if there are from 1 to 9 buildings in the area I must enter 2 one digit used for the Building call sector if there are more than 10 buildings in the area I must enter 02 two digits used for the Building call sector AREA GS Area EP Area BUILDING 1 Floor 5 Apartment 1 Apartment 2 Apa...

Page 7: ...all The lift action depends on the functions of the lift control unit BTicino cannot define these functions They depend on the lift manufacturers It is necessary to enable the function in Settings setting It is possible to display some wiring diagram examples in the Example diagrams lift control section For more information see the Lift Control Interface item 375010 software manual CCTV cameras CC...

Page 8: ...l 8 1 LED for the shooting field lighting 2 Camera 3 Light sensor 4 Display 4 3 5 Badge reader for door lock opening 6 Loudspeaker 7 Backlit keyboard 8 Finger print reader only 374001 9 Microphone 10 Locking screws Front and rear view 1 1 2 3 4 5 6 7 9 8 10 ...

Page 9: ...ower supplies identified with item no 375002 Connect the cat5 5e 6 FTP or cat5 5e 6 UTP cable with ferrite supplied to the connector 11 Mounting bracket 12 Tamper switch 13 Connection clamp 14 Not used 15 USB Connector not used 16 RJ45 Connector 17 Reset setting password and local access code 18 Not used 15 16 17 18 13 14 13 12 11 ...

Page 10: ...OPEN GND local door lock release pushbutton connection RS485A terminal B 12V GND OPEN access control devices power supply additional power supply clamps OPEN third party access control signal input for door lock opening 12Vdc pulse GND system common ground terminal for third party connection NC interlocked contact SENSE door lock status signal input dry contact C LOCK electric door lock connection...

Page 11: ...tallation heights To ensure proper operation the Fingerprint Reader only 374001 must be installed in a location protected from rain 160 165 cm 90 130 cm 53 50 cm 50 cm 80 Recommended height unless different regulations are specified 374001 400 mm 160 mm 58 mm 12 mm 374003 400 mm 160 mm ...

Page 12: ...Entrance Panel keyboard 4 3 User and installation manual 12 Installation Attention the RJ45 cable must be at least 200 mm long 149 mm 384 mm 60 mm 2 3 1 375006 ...

Page 13: ...Entrance Panel keyboard 4 3 User and installation manual 13 3 2 1 ...

Page 14: ...Entrance Panel keyboard 4 3 User and installation manual 14 2 mm 58 mm 1 2 ...

Page 15: ...el keyboard 4 3 User and installation manual 15 Adjust the tamper screw so that it presses the tamper switch of the device and activates the anti theft function in case of removal sending an alarm to the GS 1 2 3 4 ...

Page 16: ...Entrance Panel keyboard 4 3 User and installation manual 16 Uninstall 1 2 3 4 5 6 ...

Page 17: ...OUPUT 24 V 3 83A L N V V V V 1 2 DC24V OUT 1 8 DC24V DC24V DC24V DC24V DC24V DC OUTPUT 24V 4 5A 100 240V 50Hz 60Hz AC INPUT 374005 RJ45 RJ45 RJ45 RJ45 373001 374000 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 373001 373001 374000 374001 374003 374005 375005 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 375002 373001 374001 374003 374004 374004 PoESwitch BTicino 100 240Vac 100 240Vac Router Router 24Vdc...

Page 18: ...1 373001 373001 373001 373001 373001 373001 373001 373001 373001 373001 375002 375005 375005 374001 374003 375000 374001 374003 375000 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 375002 375002 375002 375002 374004 374005 FLOOR2 FLOOR3 FLOO...

Page 19: ...75005 375005 374001 374003 375000 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 373001 373001 373001 373001 373001 373001 373001 373001 373001 373001 373001 373001 375002 375000 374001 374003 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 FO FO FO FO FO RJ45 RJ45 RJ45 375002 375002 375002 373001 373001 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 375002 37...

Page 20: ...o 100 240Vac Router Note to connect the devices it is possible to use both types of wiring diagram A or diagram B or even mixed ones Attention do not directly connect PoE ports to an unsuitable network interface such as a device powered by a different voltage Connect the UP LINK port to a suitable port never to a PoE port 375010 Lift Control CentralUnit LiftControl 9 24Vdc RJ45 375001 PCclient Ser...

Page 21: ...RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 375002 375002 375002 375000 374001 374003 375002 RJ45 Router RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 FLOOR1 FLOOR2 FLOOR3 Networkswitch Networkswitch Networkswitch PoESwitchBTicino PoESwitchBTicino PoESwitchBTicino 100 240Vac 100 240Vac 100 240Vac PoESwitch BTicino 100 240Vac APARTMENT 1 A...

Page 22: ...375002 375002 375002 375002 375000 375000 374001 374003 375002 375002 RJ45 Router RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 FLOOR2 FLOOR2 FLOOR3 FLOOR3 FLOOR1 FLOOR1 RISER1 RISER2 Networkswitch Networkswitch Networkswitch Networkswitch Networkswitch Networkswitch PoESwitch BTicino PoESwitch BTicino PoESwitch BTicino PoESwitch BTicino PoESwitch BTicino PoESwitch BTicino 100 240Vac 100 ...

Page 23: ...5 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 375002 375002 375002 375000 374001 374003 375002 RJ45 Router RJ45 RJ45 RJ45 RJ45 RJ45 FLOOR1 FLOOR2 FLOOR3 Networkswitch Networkswitch Networkswitch PoESwitchBTicino PoESwitchBTicino PoESwitchBTicino 100 240Vac 100 240Vac 100 240Vac PoESwitch BTicino 100 240Vac APARTMENT 1 APARTMENT...

Page 24: ...EVICE DEVICE DEVICE Floor 4 Apartment 1 Apartment 2 Apartment 1 Apartment 2 DEVICE DEVICE DEVICE DEVICE Floor 3 Apartment 1 Apartment 2 Apartment 1 Apartment 2 DEVICE DEVICE DEVICE DEVICE Floor 2 Apartment 1 Apartment 2 Apartment 1 Apartment 2 DEVICE DEVICE DEVICE DEVICE Floor 1 Apartment 1 Apartment 2 Apartment 1 Apartment 2 DEVICE DEVICE DEVICE DEVICE RISER 1 RISER 2 EP Building BUILDING 2 Floor...

Page 25: ...e configuration and systems connected to the device The Home Page with all the functions enabled is shown below A Current date B Current time C Data field for call to IU D Navigation keys E Confirmation key F GS call key G Key for access via Access Code or access to configurations from device H Data entry keys I Back key A B C F D E G H I H ...

Page 26: ...Enter the address in the IU Community the device helps you by showing the fields to be entered e g 01 04 02 2 Touch to send the call Call using the address in the Community Touch to change the type of keypad numbers letters 1 Enter the alphanumeric code created using the DES Server software e g B12 2 Touch to send the call Call using the Alias alphanumeric code 1 2 1 2 1 B12 1 Note in the alphanum...

Page 27: ...r and installation manual 27 3 Touch to end the call A Call duration B Address in the IU Community Note the caller display depends on how the community has been configured using the software For details see Fundamental concepts A B 3 ...

Page 28: ...hine A message indicates that the call is ended Answering machine If the IU does not answer within 30 seconds it is possible to leave a message If the IU does not answer within 30 seconds a message appears 1 Touch to record the message 2 You have 30 seconds to leave a message The IU will receive a voice message 3 Touch to end 1 3 2 ...

Page 29: ...es are sent to the community via SW the device displays them in two ways during a call before the IU answers when the screen saver is activated Community message messages coming from the GS Emergency notification emergency messages coming from the system manager Messages displayed as screen saver ...

Page 30: ...function allows to call the reference GS set in the Settings Guard station section 1 Touch to call the GS A GS address Note the caller display depends on how the community has been configured using the software For details see Fundamental concepts 2 Touch to end the call 1 A 2 ...

Page 31: ... Access using a badge or card configured with SW Face recognition Access by face recognition Need to record the face using SW only for item 374000 Finger print Access by fingerprint recognition Need to record the fingerprint using SW only for item 374000 Correct operation requires the configuration of the code from the IU and a resident associated with the apartment in the SW see SW Community Pers...

Page 32: ... my community i e the EP closest to the apartment chosen from those to which I have access Example if they are enabled to all the accesses complete Area Building Riser Floor Apartment structure I open the Apartment EP This code does not work on community area building EPs Panic access code opens the door and at the same time sends an alarm message to the guard station Example if a criminal forces ...

Page 33: ...Entrance Panel keyboard 4 3 User and installation manual 33 Beeps and visual warnings will confirm that the code has been recognised and the door lock will open Door opened ...

Page 34: ...s function you can access the building using a badge or a card To use this function the badge or card must be saved in the system via SW 1 Move the badge or card on the reader Beeps will confirm that the badge card has been recognised and the door lock will open T R A N S P O N D E R 1 Door opened ...

Page 35: ...lly without entering a code To use this function your face must be saved in the system via SW 1 Position yourself so that the camera can frame your face and the system activates the recognition process Beeps will confirm that the face has been recognised and the door lock will open 1 Attention to use this function do not disable the proximity sensor see Setting proximity sensor Door opened ...

Page 36: ... recognise your fingerprint and you can enter the building automatically without entering a code To use this function your fingerprint must be saved in the system via SW 1 Position your finger in contact with the fingerprint reader A beep will confirm the correct recognition of the fingerprint and the door lock will open Door opened ...

Page 37: ...form a wide range of configurations that will enable you to make the most of your EP Access to this section is protected by a password which can be set by the SW 1 Touch to access the Settings section 2 Enter the system code to access the configuration section default 2000 3 Touch to confirm 1 2 3 2 Note for safety reasons modify the code ...

Page 38: ...eset command Setting It enables different functions Date and time It sets the date and time Access code It sets the access code in the Setting menu and the local access code to open the gate Guard station It sets the EP reference GS Door lock It sets different parameters of the EP door lock Background It sets the interface background Information It displays different information on the device Lang...

Page 39: ... Info management It displays information about messages in progress Face settings It sets the parameters for the Face Recognition Address In this section it is possible to display the different device parameters It is also possible to restore the factory settings of the device 1 Touch to reset the device Warning after confirmation all customisations will be deleted and the parameters will be resto...

Page 40: ...rm It enables the EP tamper alarm to protect the EP from removal by intruders Local password It enables the customised code to activate automatically the display and its functions Proximity sensing It enables the proximity sensor to access automatically 1 1 3 4 5 1 Touch to scroll through the items and touch to enable disable the selected feature or 2 Touch the number corresponding to the item tha...

Page 41: ... to save the settings and exit or 4 Touch to return to the Home Page without saving the settings 1 1 2 4 3 As default all the devices on the system have date and time aligned with those of the Server However it is possible to set the date and time of the single device in this section Note you can change the date time only temporarily During the night the server will realign date time to the system...

Page 42: ...lation manual 42 Automatic setting 1 Touch to enable automatic time and date update On or to disable automatic time and date update Off 2 Touch to save the settings and exit or 3 Touch to return to the Home Page without saving the settings 1 3 2 ...

Page 43: ...to move to the next field 4 Enter the new code 5 Touch to move to the next field 6 Enter the new code again to confirm 7 Touch to save the settings and exit or 8 Touch to return to the Home Page without saving the settings 1 Touch to choose Settings or Local 2 Enter the new code 6 digits 3 Touch to move to the next field 4 Enter the new code again to confirm 5 Touch to save the settings and exit o...

Page 44: ...rence GS intercepts and manages the calls to the IU or anyone called directly by pressing the key see the Call a GS section A Address of the current reference GS 1 Touch to modify the reference GS 2 Touch to select the new GS 3 Touch to save the settings and exit or 4 Touch to return to the Home Page without saving the settings 1 2 2 A 4 3 ...

Page 45: ...for more than 2 minutes Not used never sends alarm The alarm is displayed on both the SSDES and GS B Electric lock setting The lock connected to the Lock Lock clamps can be controlled using pulse or timed commands It sets the impulsive or timed mode C It restores the factory settings D Unlock time if point B is set on Timed mod set the contact activation time in seconds 1 Touch to scroll through t...

Page 46: ...h to save the settings and exit or 3 Touch to return to the Home Page without saving the settings Note it is possible to select other backgrounds or create new ones using the SW 1 1 2 3 Information In this section it is possible to display different information on the device A Item code B Device address in the Community D Versions of the different device components B C A C ...

Page 47: ...using the QR code 1 Using a smartphone scan the QR Code 2 Search for the 374001 374003 code 3 Download the manual 1 1 Touch to select the language 2 Touch to save the settings and exit or 3 Touch to return to the Home Page without saving the settings Language In this section it is possible to set the interface language 1 1 2 3 ...

Page 48: ...klighting B It adjusts the ringtone volume C It adjusts the call volume D It adjusts the tone volume when a key is pressed E It adjusts the screen saver activation time 1 Touch the number corresponding to the item that you want to select e g 2 2 Touch to adjust the parameters 3 Touch to save the settings and exit or 4 Touch to return to the Home Page without saving the settings 2 2 A B C D E 1 3 4...

Page 49: ...to return to the Home Page without saving the settings A Set if the EP is Slave EP i e not directly connected with the lift interface via RS485 but uses another EP as gateway B Select the brand C Select the floor where the EP is located D Enter the IP address of the Master EP only if EP is slave 1 Touch to scroll the items 2 Touch to change the selected function 3 Touch to save the settings and ex...

Page 50: ...essage ID A B C D Ringtone In this section it is possible to display and listen to the tones associated to the different types of ringtones or other A Alarm tone B Call in progress tone ringback C Confirmation key tone D Ringtone not used future use 1 Touch to scroll through the items and listen to the various tunes or 2 Touch the number corresponding to the item that you want to select e g 0 to l...

Page 51: ...only confirmed if someone is in front of the EP DEFAULT Colour in this mode the face is only checked by the colour camera DAY Infrared in this mode the face is only checked by the infrared camera NIGHT B Sets the level of face recognition accuracy and therefore the degree of security 0 lower level of accuracy and security 0 8 higher level of accuracy and security higher possibility of failed recog...

Page 52: ...se parameters if absolutely necessary I Enter the distance from the proximity to activate the recognition function J Enter the time from when the Home Page appears to when the Face recognition function starts During the face recognition any other operation is inhibited even the call This time is important if the Face recognition is unsuccessful You must thus set a time which is long enough for you...

Page 53: ...Entrance Panel keyboard 4 3 User and installation manual 53 ...

Page 54: ...SpA reserves the right to change at any time the content of this manual and to communicate the changes made in any form and in any way deemed appropriate BTicino SpA Viale Borri 231 21100 Varese www bticino com ...

Reviews: