9
Terraneo
Connectors and connections
The installation must only be carried out by qualified technical
staff: incorrect connection of the peripheral units may cause
the keypad to be isolated from the rest of the system.
Installation example
Installation controlled by one operator with one monitor: the
operator controls one pan & tilt motor and the following camera
functions FOCUS, ZOOM:
Cables
Different types of line have been used in the previous
examples, to indicate cables with different functions:
video cable:
RG 59 coaxial cable or equivalent cable
multipolar cable:
each control function of the positioning device is
activated/deactivated by a relay inside the receiver.
Note:
We recommend the use of different multipolar cables for
high voltage and low voltage functions.
Minimum section
area recommended: 0.56 mm
2
(AWG 20) for high voltage wires
(positioning device)
0.34 mm
2
(AWG 22) for low voltage wires
(lens).
Pan & tilt motor connection to control units
In the following drawing, identify terminal block J1 in the lower
printed circuit to connect the pan & tilt motor to the control units:
MATERIAL USED
Control keypad:
- 1 item No. 391805 control keypad
Video handling:
- 1 monitor
Telemetry handling:
- 1 item No. 391804 pan & tilt motor
- 1 item No. 391628 motorized zoom lens
7-wire-cable
to control the
pan & tilt
motor head
6-wire-cable
to control
the lens (*)
item No. 391805
(*) Only 4 wires are used.
The 2 wires to control the lens
are not used.
GB