Operation
- 3.36 -
SMART 200 MTC
COM TEST - Testing the Efficiency Rate over the Communications Line between the
SMART 200 MTC Terminal and Sensors
SETUP
CONFIG
TEST
COM
This function allows you to check the perfect operation of the communications line
between the SMART 200 MTC Terminal and connected Sensors.
It is advisable to run this check during the first testing phase (immediately after
installation) and each time random problems occur in the system operation, which
may have been caused by inefficient communications between the Sensor and the
Terminal (for example: Defects along the yarn which have not been signaled by the
sensors).
Once you have selected the TEST function from CONFIG menu, press
to
have access to the function.
Press
to select the Communications Test
This screen indicates that the Communications Test is going to start
Press
to begin the test.
From this moment on, the system communicates repeatedly with all connected
sensors. The running test status is signaled by the flashing red LED inside ENTER
button. If there are no communications errors detected, the display shows the
message TEST CO 000/000. If communications errors are detected, the display
shows the message TEST CO XXX/YYY, where the XXX indicates the total
number of failed attempts and YYY indicates the total number of sensors where
some problems occurred.
Press
once to leave this function, or press it twice to return to the Main Menu.
A
15
Summary of Contents for IS3W/MTC
Page 1: ...SMART 200 MTC IS3W MTC METER CONTROL SYSTEM Operating Manual Rev 2 0 September 2003 ENGLISH ...
Page 14: ...Technical Data and Installation 2 6 SMART 200 MTC Page intentionally left blank ...
Page 26: ...Operation 3 12 SMART 200 MTC Enabling the SETUP Menu Functions ...
Page 28: ...Operation 3 14 SMART 200 MTC Enabling the GRAPH Menu Functions ...
Page 69: ...Operation SMART 200 MTC 3 55 Production Report Example ...
Page 70: ...Operation 3 56 SMART 200 MTC Page intentionally left blank ...
Page 78: ...Appendix A Quick Reference Symbols Key A 2 SMART 200 MTC ...
Page 79: ...Appendix A Quick Reference Symbols Key SMART 200 MTC A 3 ...
Page 80: ...Appendix A Quick Reference Symbols Key A 4 SMART 200 MTC NO NC ...
Page 81: ...Appendix A Quick Reference Symbols Key SMART 200 MTC A 5 ...
Page 82: ...Appendix A Quick Reference Symbols Key A 6 SMART 200 MTC ...
Page 83: ...Appendix A Quick Reference Symbols Key SMART 200 MTC A 7 ...
Page 84: ...Appendix A Quick Reference Symbols Key A 8 SMART 200 MTC ...
Page 85: ...Appendix A Quick Reference Symbols Key SMART 200 MTC A 9 ...
Page 86: ...Appendix A Quick Reference Symbols Key A 10 SMART 200 MTC ...
Page 87: ...Appendix A Quick Reference SMART 200 MTC A 11 Notes ...
Page 88: ...Appendix A Quick Reference A 12 SMART 200 MTC Page intentionally left blank ...