Technical Data and Installation
- 2.16 -
MULTIFEEDER
MC/PC connector
This connector makes available the following signals according to the communication standard used:
MACHINE RS232 TX
MACHINE RS232 RX
Serial line reserved to OEM system integrators for RS232 communication
(communication speed 115200 Bps)
MACHINE RS485 Tx Rx +
MACHINE RS485 Tx Rx -
Serial line reserved to OEM system integrators for RS485 communication
(communication speed 115200 Bps)
MACHINE CAN H
MACHINE CAN L
BUS Can reserved to OEM system integrators
(communication speed 1 MBps)
MC/SYNC Connector
This connector makes available the Hardware I/O signals for the machine synchronization:
PRX
Cylinder rotation signals (1 or more pulses/rev)
ZPX
Hardware “Zero Chain” signal
NEXT CYCLE
“NEXT CYCLE” signal
START/STOP
“MACHINE START/STOP” signal
EX-STOP 1
Alarm signal (to the machine stop input)
EX-STOP 2
AUXILIARY STOP signal
EXC RF+
Positive OPTO-INSULATED signal for Rollingfeeder exclusion
EXC RF-
Negative OPTO-INSULATED signal for Rollingfeeder exclusion
INPUT POLARITY
Input lines PULL/UP and PULL/DOWN activation
EXC connector
This connector makes available the Hardware I/O signals for control of FEEDER devices connected to
Groups1-2-3-4.
INC GRP 1
INC signals for Feeder devices connected to group
GRP 1
DEC GRP 1
DEC signals for Feeder devices connected to group
GRP 1
INC GRP 2
INC signals for Feeder devices connected to group
GRP 2
DEC GRP 2
DEC signals for Feeder devices connected to group
GRP 2
INC GRP 3
INC signals for Feeder devices connected to group
GRP 3
DEC GRP 3
DEC signals for Feeder devices connected to group
GRP 3
INC GRP 4
INC signals for Feeder devices connected to group
GRP 4
DEC GRP4
DEC signals for Feeder devices connected to group
GRP 4
EXC +
EXC -
EXCLUSION SIGNAL OF ALL THE FEEDERS CONNECTED