SMART KTF 2000 – KTF/RW Operation
3B-32 -
SMART KTF 2000
1.3) TIME ALARM = P1.3
Press
to enable the parameter programming
VV.V = Value of
P1.3
TIME ALARM
parameter to be associated to the article
setup. It indicates the maximum time
(in seconds)
during which the
tension value may exit from the tolerance range set by the 1.2) ERR
TENSION
parameter. You can disable
(OFF)
or re-enable this feature by
pressing
.
Choose the desired value using
,
,
[allowed values: 0.1 to 10 sec.].
Press
to move to the next parameter.
1.4) TENS INC-DEC = P1.4
Press
to enable the parameter programming
VV.V = Value of parameter
P1.4
INC-DEC TENSION
parameter to be
associated to the article setup. It indicates the increment/decrement
resolution of the Tension graduated by the external INC/DEC command
pulses..
Choose the desired value using
,
,
[allowed values: 0.1 to 10 grams].
Press
to move to the next parameter.
1.5) METR INC-DEC (Available on SMART KTF-2000 only)
This parameter allows you to automatically graduate the yarn winding tension on
the bobbin at predefined intervals of meters, rather than using external INC-DEC
signals.
In particular, this parameter defines every how many meters the yarn tension
(MAIN TENSION) must be either incremented or decremented by the fixed
amount declared with the previous parameter 1.4) TENS INC-DEC.
When reaching the TARGET defined in 1.6) METR TARGET, the automatic
graduation is reset.
This feature allows you to change the softness of the bobbins during the rewinding
process, to make the dye-works easier, and it may help to obtain perfectly shaped
bobbins.
Summary of Contents for SMART KTF 2000
Page 1: ...SMART KTF 2000 YARN CONTROL SYSTEM Operating Manual ENGLISH Rev 2 0 June 2003 ...
Page 6: ......
Page 16: ...Technical Data and Installation 2 6 SMART KTF 2000 Page intentionally left blank ...
Page 20: ...SMART KTF 2000 OPERATION 3 4 SMART KTF 2000 Page intentionally left blank ...
Page 22: ...SMART KTF 2000 KTF 100HP Operation 3A 2 SMART KTF 2000 Page intentionally left blank ...
Page 68: ...SMART KTF 2000 KTF 100HP Operation 3A 48 SMART KTF 2000 Page left intentionally blank ...
Page 70: ...Operatività SMART KTF 2000 KTF RW 3B 2 SMART KTF 2000 Page left intentionally blank ...
Page 120: ...Troubleshooting and Maintenance 4 4 SMART KTF 2000 Page left intentionally blank ...
Page 141: ...Appendix B Quick Reference SMART KTF 2000 KTF RW SMART KTF 2000 B 9 Symbols Key ...