SMART KTF 2000 – KTF/RW Operation
SMART KTF 2000
3B-33 -
Example:
1.5) MAIN TENSION=
10g
1.6) TENS INC-DEC=
0,1g
1.7) METR INC-DEC=
+000100 m.
1.8) METR TARGET=
10000 m.
The initial tension (10g) is increased by 0.1g every 100 metres; when reaching the target (10000m) it
returns to 10g.
For more details and application examples, please refer to KTF/RW
Operating Manual.
Press
to enable the parameter programming
OFF= Function disabled; to enable it press and hold down
for 3 seconds
+ =
Increment
- =
Decrement
Press and hold down
for 3 seconds to switch from + to – or
for – to OFF.
Set the desired value: every how many meters the MAIN TENSION (P1.1) value
must be increased/decreased by the amount specified by METR INC-DEC (P1.5)
parameter.
increases the value by 1
decreases the value by 1
+
increases the value by 1000
+
decreases the value by 1
After having set the desired value, press
to continue
Summary of Contents for SMART KTF 2000
Page 1: ...SMART KTF 2000 YARN CONTROL SYSTEM Operating Manual ENGLISH Rev 2 0 June 2003 ...
Page 6: ......
Page 16: ...Technical Data and Installation 2 6 SMART KTF 2000 Page intentionally left blank ...
Page 20: ...SMART KTF 2000 OPERATION 3 4 SMART KTF 2000 Page intentionally left blank ...
Page 22: ...SMART KTF 2000 KTF 100HP Operation 3A 2 SMART KTF 2000 Page intentionally left blank ...
Page 68: ...SMART KTF 2000 KTF 100HP Operation 3A 48 SMART KTF 2000 Page left intentionally blank ...
Page 70: ...Operatività SMART KTF 2000 KTF RW 3B 2 SMART KTF 2000 Page left intentionally blank ...
Page 120: ...Troubleshooting and Maintenance 4 4 SMART KTF 2000 Page left intentionally blank ...
Page 141: ...Appendix B Quick Reference SMART KTF 2000 KTF RW SMART KTF 2000 B 9 Symbols Key ...