Comunication Test
SMART MATRIX MTC
2 - 19
Communication Test
This function allows you to check:
- The efficiency level of communications between SMART MATRIX and SM-DIN Boards and between SM-
DIN Boards and Sensors.
- The correct operation of Sensors.
- The correct operation of DACS (option).
Communication Efficiency
Enter the
SETUP
menu.
Select
TEST COM
.
Select
COMM. EFF.
to check the efficiency level of
communications.
Select
GLOBAL
(
global efficiency
) or
SINGLE
(
communication efficiency with each sensor
).
Number of sensors on which communication errors
occurred
(
DEV IN ERROR
)
and total number of
transmission repeated as result of detected errors (
TOTAL
RETRY
). A maximum of 5 transmission are repeated for
each sensor.
Global efficiency index.
Like for
GLOBAL
option, but referred to the selected Board
only. (
e.g.:
BOARD NUMBER:1
)
Efficiency index of Board 1.
SETUP
→
TEST COM
SETUP
→
TEST COM
→
COMM. EFF.