Comunication Test
SMART MATRIX MTC
2 - 20
Sensor Test
Enter the
SETUP
menu.
Select
TEST COM
.
Select
MTC TEST
. (
“ENTER TEST MODE” will appear for
a few seconds
)
Select the sensor you want to test (
SIDE
: XX,
SECT
: NN,
DEV
: NN
) (
the selected sensor shall have the red led
blinking
).
To return to previous menu
.
(
“EXIT TEST MODE”
will
appear for a few seconds
)
If the GLOBAL Test shows an error (e.g.: 001/005 which means that one sensor does not correctly
communicate with the system), then operate as follows:
1.
Run the SINGLE Test to locate the Board which the defective sensor is connected to.
2.
Select the Sensor Test and confirm the correct red Led blinking (the sensor which does not
show the red led blinking is the defective or disconnected one.
SETUP
→
TEST COM
→
MTC TEST