IS3W/MTC Sensor Features
SMART MATRIX MTC
3 - 7
Interpretation of the signaling lights located on the sensors
Green LED ON
Normal operation, the yarn
is running
inside the
sensor;
No technical failure detected by the sensor.
Green LED BLINKING
Sensor in automatic numbering phase.
Red LED ON
Normal operation, the yarn
is not running
inside the
sensor;
Red LED BLINKING
During machine operation the sensor has detected a
failure
(broken yarn)
and currently the yarn is steady.
Green LED ON
Red LED ON
Stopped sensor. Switch off, then switch on the
system. If the condition is permanent, replace the
sensor.
Green LED OFF
Red LED OFF
Sensor not powered.
Green LED BLINKING
Red LED BLINKING
1)
TARGET reached.
2)
Fault in the sensor
(e.g. a loss of data)
. You must
re-program the device. This type of failure only
occurs at power on.
Green LED ON
Red LED BLINKING
During machine operation the sensor has detected a
failure
(broken yarn)
, but currently the yarn is running
again.
Summary of Contents for SMART MATRIX MTC
Page 1: ...SMART MATRIX MTC Operating Manual ENGLISH Rev 1 0 September 2010 ...
Page 3: ...Introduction i ...
Page 4: ......
Page 9: ...Connections and Electrical Interface 1 ...
Page 10: ......
Page 17: ...Operating Instructions 2 ...
Page 18: ......
Page 71: ...System Information 3 ...
Page 72: ......