Technical Data and Installation
ULTRAFEEDER
- 2.1 -
2 – TECHNICAL DATA AND INSTALLATION
Technical Features
ULTRAFEEDER Device
Power supply voltage
24 VDC ± 10%
Maximum absorption
0,2A
(during normal operation);
1A
(under stress);
3A
(at start-up)
STOP Output
NPN Open Collector, 200 mA max.
Max. voltage
(INC/DEC inputs,
STOP Output)
30 VDC
Programmable yarn tension
0.2 ÷ 100,0 gr.
(resolution 0.1 gr.)
Programmable alarms
0.1 ÷ 10 sec.
Integrated keypad
3 push-b STOP red LEDs
Signaling
With LCD graphic display
Dimensions
159 x 63 x 76 mm
Operating temperature range
10° - 60 °C
Storage temperature
-25° - +85° C
Tension range
0 / full scale
Useful tension range
0% - 95% full scale
Max applicable tension
10 times the full scale value
Drift error (a)
0.05% / °C
Repeatability error (b)
0.5%
Max linearity error (c)
1%
(0 / full scale)
Max error (a + b +c)
2%
Rising / falling time
1.5 ms
Resonance frequency
150 Hz
SMART MATRIX FEEDER and SMART MATRIX PFU Terminal
Power supply voltage
24 VDC ± 10%
Maximum absorption
100 mA
Dimensions
140 x 80 x 31 mm
Operating temperature range
10° - 60 °C
LCD graphic display
80 x 40 mm
Integrated Touch-pad
6 b rotary selector
Protection
2 fuses – 1.5A
Power supply KTF/PW4 (6 + 6 outputs)
Power supply voltage
24 VAC ± 20%
Output voltage
2 x 24 VDC ± 5%
(standard)
2 x 32 VDC ± 5%
(boost)
Max output current
2 x 20A
(peak)
2 x 10A
(continuous)
Dimensions
115 x 135 x 55 mm
Operating Temperature range
10° - 60 °C
Signaling
8 LEDs: POWER ON, EXC,
INC, DEC, STOP
(Group 1)
INC, DEC, STOP
(Group 2)
Protection
1 fuse 5 x 20 – 10A
Summary of Contents for ULTRAFEEDER
Page 1: ...ULTRAFEEDER YARN CONTROL SYSTEM Operating Manual ENGLISH Rev 4 1 February 2017 ...