Operation
ULTRAFEEDER
- 3-5 -
Programming the ULTRAFEEDER Devices
The ULTRAFEEDER device offers two programming environments:
1)
SIMPLE
(allows programming exclusively the device main tension)
2)
ADVANCED
(allows programming all the device parameters)
To have access to the programming environment, press and hold down for 3 seconds the
ENTER button, while the device is operating in Control environment.
If you keep the button pressed for less than 3 seconds, the device Firmware version will
temporarily appear on the display.
To switch from
SIMPLE
to
ADVANCED
and viceversa, press and hold down for 3 seconds
the ENTER button.
To avoid undesired changes of operating parameters, after the installation of
ULTRAFEEDER devices and after having setup and checked all the working
parameters in
ADVANCED
programming environment, it is advisable to activate the
SIMPLE
programming environment, so that when the operator will subsequently enter
the programming environment, he/she will only have the possibility to change the
main tension (1
st
variable of P1).
General Diagram of Simple Programming Environment
(A)
LFA = Length of Absorbed Yarn in m/min