Operation
ULTRAFEEDER
- 3-15 -
P3 Programming Level
LFA m/min
Î
ADVANCED
Î
MENU P3
The P3 programming level allows you to setup 4 functionality:
1)
Offset reading/execution and Auto Offset enabling;
2)
Device operation mode;
3)
Access code to programmable function;
4)
ULTRAFEEDER identification code.
to select the P3 level.
to continue.
P3.1
OFFSET
This function is used to adjust the mechanical clamping position of
ULTRAFEEDER device. It clears possible measurement errors due to the different
clamping position of the device on textile machine. The displayed indication is the
actual
OFFSET
value resulting from the clamping position of the device.
While lifting the yarn above the loading cell, press
to check whether the
stored
OFFSET
value corresponds to the
actual
OFFSET
value. If the two values are
different, press briefly
to align them.
Auto-Calibration of the Loading Cell
Holding down
for 3 seconds you may activate the loading cell Auto-
Calibration function which brings back the Offset value to 5.0 grams
(factory
calibration value of Ultrafeeder devices)
.
During the auto-calibration process, an “
OFFSET INT
-
CALI
” message is temporarily
shown on the display.
to select the next parameter.
Summary of Contents for ULTRAFEEDER
Page 1: ...ULTRAFEEDER YARN CONTROL SYSTEM Operating Manual ENGLISH Rev 4 1 February 2017 ...
Page 40: ...Technical Data and Installation 2 28 ULTRAFEEDER Page intentionally left blank ...
Page 72: ...ULTRAFEEDER Troubleshooting and Maintenance 4 6 ULTRAFEEDER Page intentionally left blank ...
Page 78: ...YTT Device 5 6 ULTRAFEEDER Page intentionally left blank ...