1.TECHNICAL FEATURES 

* Power supply:  6 Volts (4 batteries, type AA, R6 or equivalent).  Look at the sell-by date on the batteries. Alkaline batteries 

recommended. Watch out carefully for the 

expiration date 

of the batteries before installing them in your safe. Do not use 

rechargeable batteries. Check and replace the batteries every year. 

* One user code (4 digits) plus one emergency code (8 digits). 
* Automatic blocking system for 5 minutes when more than 10 consecutive incorrect codes are entered. 
* Low batteries’ warning system. 
* Inside easy access to replacement of batteries. 
* External power supply, to open your safe in case the batteries are completely discharged

 
Read carefully these instructions and warranty before any action. 
 
IMPORTANT!

 

Check every

 action with 

open door

before 

closing it. 

 

2.  FIRST USE 

2.1.

 

 Fit four batteries as indicated on point 6 of this instruction manual. 

2.2.

 

 Then open and close the safe several times (point 3). 

2.3.

 

 Change the original user code for your own one (point 4) 

 

3. OPENING/CLOSING INSTRUCTIONS 

3.1. Introduce your 

code number

.  All the safes have the code 

1 2 3 4 5 6 

programmed when used for the first time.  After 

you press each digit, there will be a short beep and the red light will turn on.  If you do not press any key for 7 
consecutive seconds, the unit will disconnect; in this case, start again from the beginning. 

3.2. If the code entered was correct, the green light will turn on and the bolts will move to the open position while this light 

stays on.  When the green light turns you could open the door. 

3.3. To close the safe, close the door and enter the code.  The red light will turn on while the bolts move.  In case the bolts 

find some obstacle when closing, you will hear five beeps, the red light will turn on, the bolts will retrieve to the open 
position and the safe will keep open.  Locate and remove the obstacle, close the door and enter the code to close the 
safe. 

Opening/closing example:   

1 2 3 4 5 6

 

 
4. PROGRAMMING OR CHANGING YOUR CODE 
A. User code

: every safe has been programmed with the same user code.  

For your security

 

do not forget to change it

A.1. Open the safe following the instructions for opening (point 3). 
A.2. Press the key 

“#/Reset

”; the red light will turn on and a programming tone will be heard.  

A.3.  Introduce  your  current  code  (from  factory,  the  number  1  2  3  4  5  6).  If  the  code  is  correct,  you  will  hear  the 

programming tone.  

A.4. Enter the 

new code

 (from 2 to 15 digits), followed by the key “

C

”. After this, you will hear again the programming tone. 

A.5. Finally, introduce again the 

new code

, so as to confirm it.  A programming tone will be heard, the green light will turn 

on,  indicating  that  the  new  code  has  been  programmed,  and  the  bolts  will  move  to  the  closed  position.    If  the 
programmation was not corretly done, you will hear the error tone and you should start from step A.2. 

A.6. Before closing the door, check the new code at least 

three times

, following the opening instructions. 

 
Example of programming: 
 

 

A.1. 

1 2 3 4 5 6 

 

current code to open the safe 

 

 

A.2.   

#/Reset   

 

press the key “#/Reset” 

 

 

A.3.  

1 2 3 4   

 

introduce current code 

 

 

A.4.   

9 7 6 5 C  

 

introduce new code + key “C” 

 

 

A.5.   

9 7 6 5    

 

repeat the new code 

 

B.  Emergency  code

:  Every  safe  has  been  programmed  with  an 

exclusive  emergency  code

.  We  recommeded  you 

not  to 

change it

. If you wish to change it, please follow carefully the next sequence: 

B.1. Open the door with your emergency code (see point 5)  
B.2. Press the key 

“#/Reset

”; the red light will turn on and a programming tone will be heard.   

B.3. Introduce your current code (from the factory, the one in the enclosed envelope). If the code is correct, you will hear 

the programming tone.  

B.4. Press the key “

2

”. 

B.5. Press the key 

“#/Reset

”; the red light will turn on and 2 short beeps will be heard. 

B.6. Enter the 

new code

 (from 2 to 15 digits) followed by the key “C”.  After this, you will hear again the programming tone. 

Summary of Contents for DVR

Page 1: ...la caja sin cerrar Localice el objeto o la dificultad que impide que los cerrojos se desplacen retírelo cierre la puerta y teclee la combinación de cierre Ejemplo de apertura y o cierre 1 2 3 4 5 6 4 PROGRAMACIÓN CAMBIO DE COMBINACIONES A Código de usuario Todas las cajas salen de fábrica con la misma combinación Para su seguridad no olvide cambiarla A 1 Abrir la caja con el actual código de usuar...

Page 2: ... activa un retardo que bloquea la apertura de la caja durante 1 a 99 minutos desde el momento que se teclea el código de usuario Durante el tiempo que dura el retardo parpadea la luz roja y no se puede abrir la caja Al pasar el tiempo establecido el sistema desbloquea el cierre emite un pitido corto y permite la apertura de la caja durante 5 segundos Para activar o desactivar esta función la puert...

Page 3: ...will retrieve to the open position and the safe will keep open Locate and remove the obstacle close the door and enter the code to close the safe Opening closing example 1 2 3 4 5 6 4 PROGRAMMING OR CHANGING YOUR CODE A User code every safe has been programmed with the same user code For your security do not forget to change it A 1 Open the safe following the instructions for opening point 3 A 2 P...

Page 4: ...ew alkaline ones Alkaline batteries are recommended for long life and armour 6 OPENING DELAY PROGRAMMATION This function activates a delay which blocks the opening of the safe for 1 to 99 minutes after the user code has been entered The red light flashes during the delay time and when it is over a short beep will be heard the system unblocks and allows the opening of the safe for 5 seconds To acti...

Reviews: