B.7. Finally, introduce again the 

new code

, so as to confirm it.   A programming tone will be heard, the green light will turn 

on,  indicating  that  the  new  code  has  been  programmed  and  the  bolts  will  move  to  the  closed  position.  If  the 
programmation was not correctly done, you will hear an error tone and you should start form step B.2. 

B.7. Before closing the door, check the new code at least 

three times

, following the opening instructions. 

 
Example of programming the emergency code: 
 

 

B.1. 

8 7 6 5 4 3 2 1 

 

(open with the emergency code) 

 

 

B.2.   

#/Reset   

 

(press the key “#/Reset) 

 

 

B.3. 

8 7 6 5 4 3 2 1  

 

(introduce current emergency code) 

 

 

B.3.   

 

 

(press the key “2”) 

 

 

B.4.  

#/Reset   

 

(press the key “#/Reset) 

 

 

B.5. 

7 6 1 0 8 4 2 2 C    

(introduce new emergency code + key C) 

 

 

B.6.   

7 6 1 0 8 4 2 2 

 

(repeat new emergency code) 

 
BEWARE!: If you omit steps B.3. and B.4., you will always modify the user code 1. 

NOTE:

    We  strongly  suggest  that  you  program  code  numbers  which  are  easy  for  you  to  remember,  such  as  friends’ 

telephone numbers, birth dates, car licence plates, etc..  Do not trust memory, and do 

write and keep your code number in 

two different secret places for not mislaying it

 

5. EMERGENCY OPENING 

Your safe is provided  with an 

envelope

 which contains: 

5.1. 

One emergency code number

 to open your safe in case that you have forgotten your normal opening code number.  

Enter your emergency code number as usual.  The green light will turn on, showing that you can now open your safe.  
For your security 

the emergency code should be changed

, so do as explained in point 6.B. 

5.2. 

External power supply

, to open your safe in case the batteries are completely discharged. To use it, put an 

alkaline

 9V 

battery (6F-22 S type) against the two black dots in the keypad, watching out that the polarity is correct.  Then, while 
holding the 9V battery on the keypad, introduce your  code number, and open your safe as usual. As soon as you have 
opened your safe, do not forget to replace all four batteries for new alkaline ones. Alkaline batteries are recommended 
for long-life and armour. 

 
6. OPENING DELAY PROGRAMMATION 

This  function  activates  a  delay  which  blocks  the  opening  of  the  safe  for  1  to  99  minutes  after  the  user  code  has  been 
entered.  The red light flashes during the delay time, and when it is over, a short beep will be heard, the system unblocks 
and allows the opening of the safe for 5 seconds.   To activate or desactivate this function, the

 door must be in the open 

position

 
a) To 

activate

 this function: 

1. Enter the following secuence: “C 1 0 0”.  The red light will turn on and you will hear the programming tone. 
2. Introduce the desired 

delay number of minutes

, from 

01 to 99

.  You will hear the programming tone. 

 

b) To 

desactivate

 this function: just program the delay with 

0 minutes 

time.  

 

 

 

 
7. OTHER FEATURES 

*

  Incorrect code number

: if the code number that you have entered is not the one programmed before, you will hear a 

special tone indicating that this code number is not correct.  In this case, go back to step 1 of the opening instructions. 

*  

Obstacle

: In case the bolts find some obstacle when closing, you will hear five beeps, the red light will turn on, the bolts 

will retrieve to the open position and the safe will keep open.  Locate and remove the obstacle, close the door and enter 
the code to close the safe.

 

*  

Blocking system

: provides  aditional security: if incorrect code numbers are entered more than 10 times consecutively, 

some  long  beeps  will  be  heard,  and  the  safe  will  stay  locked  for  5  minutes.    During  this  time,  the  red  light  will  be 
flashing, and it will be impossible to open the safe.  When the 5 minutes have gone by, you wil be able to open the safe 
as usual. 

*   

Low  batteries

:  the  system  detects  whether  the  batteries  are  very  low.    If  this  is  the  case,  you  will  hear  some  tones 

followed by the flashing red light when you press some key: you will still be able to operate your safe around 100 times, 
but it is highly recommended that you change all four batteries at that time. 

*  

Replacement of batteries

:  the batteries’ holder can be found in a compartment inside the door, under a small cover.   

Once you have removed the cover, change all FOUR batteries for new ones and secure the cover back.  Check the right 
functioning of the safe before locking it. 

 

 

Summary of Contents for DVR

Page 1: ...la caja sin cerrar Localice el objeto o la dificultad que impide que los cerrojos se desplacen retírelo cierre la puerta y teclee la combinación de cierre Ejemplo de apertura y o cierre 1 2 3 4 5 6 4 PROGRAMACIÓN CAMBIO DE COMBINACIONES A Código de usuario Todas las cajas salen de fábrica con la misma combinación Para su seguridad no olvide cambiarla A 1 Abrir la caja con el actual código de usuar...

Page 2: ... activa un retardo que bloquea la apertura de la caja durante 1 a 99 minutos desde el momento que se teclea el código de usuario Durante el tiempo que dura el retardo parpadea la luz roja y no se puede abrir la caja Al pasar el tiempo establecido el sistema desbloquea el cierre emite un pitido corto y permite la apertura de la caja durante 5 segundos Para activar o desactivar esta función la puert...

Page 3: ...will retrieve to the open position and the safe will keep open Locate and remove the obstacle close the door and enter the code to close the safe Opening closing example 1 2 3 4 5 6 4 PROGRAMMING OR CHANGING YOUR CODE A User code every safe has been programmed with the same user code For your security do not forget to change it A 1 Open the safe following the instructions for opening point 3 A 2 P...

Page 4: ...ew alkaline ones Alkaline batteries are recommended for long life and armour 6 OPENING DELAY PROGRAMMATION This function activates a delay which blocks the opening of the safe for 1 to 99 minutes after the user code has been entered The red light flashes during the delay time and when it is over a short beep will be heard the system unblocks and allows the opening of the safe for 5 seconds To acti...

Reviews: