4.0peration
4.6 Stopping
<Procedure>
CD Close the service valve completely and operate the machine about 5 minutes, until it cools down.
® Turn the starter switch to "STOP" position to stop the engine.
@ Remove the key from the compressor every time when you stop the engine. Keep the key and be
careful not to lose it.
• Unless all the service valve are fully closed upon stopping operation, the compressed air will be
sent in reverse direction in the hoses (pipes) connected to air tools and relieved to atmosphere
continuously through the auto-relief valve. Further, when re-starting operation next time,
compressed air will be jetted out through service valves.
4. 7 Air bleeding in fuel line
Should the machine stop due to fuel shortage, perform air bleeding according to the following steps.
<Procedure>
CD Replenish fuel.
® When starter switch is turned to "RUN" position, electromagnet pump starts to automatically bleed
air in fuel line.
® Air bleeding is completed about 1 minute.
4-14