3
Transportation
Logalux SM300/1 - SM400/1 - Technical specifications are subject to change without prior notice.
11
3.1.2
Transportation with overhead crane
V
Place the two lifting hooks of the chain into the desig-
nated lifting rings on top of the tank [1].
V
Hook the crane chain into the lifting chain.
V
Protect the tank from falling and lift the tank to its final
installation location.
V
Lower the tank carefully to the floor; do not drop down
onto the floor!
One can move the tank inside the building also in a hori-
zontal manner due to possible height restrictions.
V
Remove only the tank packaging at the final installation
site.
Fig. 6
Transportation with lifting crane (SM400/1)
1
Lifting eyes
3.2
Product Placement
V
Maintain suggested service access dimensions
(
Æ
Fig. 7).
V
Maintain 2" clearance from heated pipes to
combustible surfaces.
V
Place tank on a level and sufficiently strong floor.
V
Remove plastic and packaging materials.
Wandabstandsmaße
Fig. 7
Recommended minimum clearances
(in inch/mm)
1
Solar hot water heater
2
Boiler
Caution:
Damage due to internal stresses!
V
Place the tank in a frost free room.
V
Use the solar water heater ONLY in
closed loop applications.
V
Open expansion tanks can NOT be used
with these solar water heater tanks.
Minimum 12" overhead space is required for
the removal of the magnesium anode rod as
well as some side clearance.
V
Verify for suitable clearance dimensions by
referencing (
Æ
Tab. 1, page 9 und Fig. 7).