background image

3

 

Operating the appliance

Logano GB102 – 6 720 811 066 (2014/09)

5

Switching the appliance off

▶ Switch off at the with the main appliance switch.

The display goes blank.

▶ If the appliance is to be taken out of service for a while: Check the anti 

freeze (

 Section 3.8).

3.4

Heating mode

3.4.1

Heating mode on/off

▶ Press the Heating mode button 

 repeatedly until the display 

shows the Heating mode on symbol 

 or the Heating mode off 

symbol  

flashing.

Fig. 4  

Heating display

▶ Press the button 

+

 or the button

  – 

 to select Heating mode on or off:

 =Heating mode on

 = Heating mode off

▶ Press the 

ok

 button to save the setting.

The tick symbol 

 will be displayed briefly.

Fig. 5  

Heating mode display

The burner symbol    is displayed when the there is a heating 
demand.

3.4.2

Set the maximum flow temperature

The maximum flow temperature can be set between 30 °C and 82 °C

1)

The current flow temperature appears on the display. 

When in the Heating mode:
▶ Press the 

 button.

The display shows the flashing maximum flow temperature and the 
Heating mode symbol 

 is displayed.

Fig. 6  

Maximum flow temperature

▶ Press the  

+

 or

   – 

 button to set the desired maximum flow 

temperature.

▶ Press 

ok

 to save the setting.

The tick symbol

 is displayed briefly to confirm that the setting 

has been saved.

Fig. 7  

Setting the maximum flow temperature

The controller has a pump anti-seize function for when 
the pump is inactive for a long period of time, the pump 
is run periodically to prevent it seizing. If the controller is 
turned off, then this function is inactive.

NOTICE: 

Risk of the system freezing

When the heating is turn off, only the appliance is 
protected from frost.
▶ Check the anti-freeze if there is arisk of freezing 

(

 Page 7).

No heating will occur if the Heating mode has been set to 
off.

6 720 619 605-15.1O 

6 720 619 605-14.1O 

1) The maximum value can be reduced by the service technician.

For under-floor heating be aware of the maximum flow 
temperature.

Flow temperature
(approx.)

Example

 50 °C

Under-floor

75 °C

Radiators

82 °C

Convection

Table 2   Maximum flow temperatures

6 720 619 605-13.1O 

6 720 619 605-14.1O 

Summary of Contents for Logano plus GB102

Page 1: ...Vor Installation und Wartung sorgfältig lesen User Instructions Gas fired condensing boiler Logano plus GB102 GB102S System boiler16 30 Regular boiler 16 30 42 6 720 811 066 2014 03 ...

Page 2: ...ient offering you economical running costs and value for money It sits in SEDBUK 2005 Band A and is therefore amongst the top energy rated boilers available There is also the reassurance of our no nonsense 2 years parts and labour guarantee backed up by Worcester Total Cover an optional complete maintenance scheme to keep your boiler operating at peak condition and efficiency Table of Contents 1 K...

Page 3: ...SERVICING Advise the user to have the system serviced annually by a competent qualified Gas Safe registered engineer Approved spares must be used to help maintain the economy safety and reliability of the appliance IMPORTANT The service engineer must complete the Service Record on the Benchmark Checklist after each service 2 PRODUCT INFORMATION 2 1 Intended use The appliance is only for use in sea...

Page 4: ... compensation External sensor required 5 Chimney sweep mode 6 Fault alert 7 Service mode 6 7 Maintenance mode 8 Burner on 9 Temperature units C 10 Confirmation 11 Scroll up or down through the sub menus 12 Alphanumeric display e g Temperature 13 Text display 14 Heating mode off 15 Heating mode on 3 3 Appliance on off switch Initial switch on Switch on at the with the main appliance switch The disp...

Page 5: ...the button The display shows the flashing maximum flow temperature and the Heating mode symbol is displayed Fig 6 Maximum flow temperature Press the or button to set the desired maximum flow temperature Press ok to save the setting The tick symbol is displayed briefly to confirm that the setting has been saved Fig 7 Setting the maximum flow temperature The controller has a pump anti seize function...

Page 6: ...t temperature The control then switches back into heating mode 3 5 2 Setting the DHW temperature DHW or Eco mode page 6 Press the button The set DHW temperature flashes Fig 10 Pressthe or button toselectthedesiredDHWtemperature set between 40 and 60 C Press the ok button to save the setting The tick symbol is displayed briefly to confirm that the setting has been saved Fig 11 3 6 Control unit sett...

Page 7: ...rol system manual Cylinder frost protection Even when the DHW mode is switched off the cylinder is protected against frost damage Set the DHW mode to off Section 3 5 1 4 SYSTEM OPERATING PRESSURE 4 1 Check the water pressure System boiler only The normal operating pressure is between 1 and 2 bar If the pressure needs to be constantly re pressurized or the pressure is constantly over the 2 5bar mar...

Page 8: ... for relatively long periods of time but will use less gas than a boiler that continually switches on and off CENTRAL HEATING SYSTEMS WITH ROOM THERMOSTAT THERMOSTATIC RADIATOR VALVES With modern heating systems set around a 20 C heat loss the optimum setting for a condensing boiler will be approximately between the first and second segment on the central heating temperature control The system mus...

Page 9: ... ok button to save the setting The tick symbol is displayed briefly to confirm the setting Setting the optional control system See operating instructions for the control systems Setting the maximum flow temperature Press the button Press the or button the set the flow temperature Setting the DHW temperature Press the button Press the or button to set the DHW temperature Press the ok button to save...

Page 10: ...8 Logano GB102 6 720 811 066 2014 09 10 Notes ...

Page 11: ...8 Logano GB102 6 720 811 066 2014 09 11 Notes ...

Page 12: ......