Automatic mode
Hold down the "AUT" button and select the room temperature with
the dial (here: "20 °C") which is required for the heating circuit.
Release the button to store your input.
The heating circuit is now in automatic mode and the day room
temperature has been set to 20 °C. Then the selected standard
display will be shown again.
Manual mode
Press either the "Day mode" or "Night mode" button instead of the
"AUT" button:
Hold down the "Day mode" button and select the room
temperature with the dial (here: "20 °C") which is required for the
heating circuit.
The LED in the "Day mode" button lights up. Now the heating
circuit is set in constant day mode (standard heating mode).
Hold down the "Night mode" button and select the room
temperature with the dial (here: "16 °C") which is required for the
heating circuit.
The LED in the "Night mode" button lights up. Now the heating
circuit is set in constant night mode (reduced heating mode), and
operates at a lower room temperature.
+
HEAT CIRC 2
AUTO
DAY
20.0
°
+
HEAT CIRC 2
MAN
DAY
20.0
°
+
HEAT CIRC 2
MAN
NIGHT
16.0
°