2002 Buell P3: Electrical
7-9
HOME
Figure 7-7. Continuous or No Spark At Spark Plug
YES
NO
Is Bank Angle Sensor
Connected?
Reconnect.
Disconnect Connector [134].
Measure Voltage On [134B] Between Socket A, LT GN/GY And Socket B, BK
3.0-3.5 VDC
11-13 VDC
0 VDC
See Next Page
Repair Short
On LT GN/
GY Wire.
5007
YES
NO
Repair Open In
LT GN/GY Wire.
5007
Disconnect Connector [10]. Check Continuity
Between Socket A, LT GN/GY On Connector [134B]
And Socket 5, LT GN/GY On Connector [10B].
Continuity Present?
YES
NO
See Starter Interlock
Section 7.11.
Check Continuity To Ground On LT GN/GY
Wire, Socket A, Connector [134B] Or [10B].
Is Continuity Present?
5007
Check Continuity To Ground On TN/Y
Wire, Socket B, Connector [134B].
Is Continuity Present?
YES
NO
Inspect Module Harness For
Damage. Repair If Neces-
sary.
If Harness Is Not Damaged,
Replace Ignition Module.
5009
Repair Short To Ground
On LT GN/GY Wire.
5007
*
To avoid damage to terminals,
remove Bank Angle Sensor
before disconnecting connector
[134]. Use Harness Connector
Adapter Kit HD-41404,Gray
male probe and patch cord
Bank Angle Sensor
Connector [134]
Summary of Contents for 2002 P3
Page 2: ......
Page 17: ...A 15 Appendix A Tools HOME ...
Page 32: ...C 3 Appendix C Metric Conversions HOME ...
Page 41: ...1 8 2002 Buell P3 Maintenance HOME NOTES ...
Page 75: ......
Page 111: ...2 36 2002 Buell P3 Chassis HOME NOTES ...
Page 143: ...2 68 2002 Buell P3 Chassis HOME NOTES ...
Page 144: ...2002 Buell P3 Chassis 2 69 HOME ...
Page 146: ......
Page 147: ......
Page 223: ...3 76 2002 Buell P3 Engine HOME NOTES ...
Page 225: ......
Page 256: ...2002 Buell P3 Fuel System 4 31 HOME ...
Page 258: ......
Page 259: ......
Page 279: ...5 20 2002 Buell P3 Electric Starter HOME NOTES ...
Page 281: ......
Page 327: ......
Page 398: ...2002 Buell P3 Electrical 7 71 HOME ...
Page 400: ...Product 1 2 ...