4-84
2004 Buell Lightning: Fuel System
HOME
TROUBLE CODE 44
4.27
GENERAL
NOTE
See
Figure 4-57.
When vehicle lean angle causes weighted
pendulum to enter shaded area for a period of greater than
one second, ECM shuts off ignition and fuel systems.
Bank Angle Sensor
See
Figure 4-58.
A Code 44 occurs when the bank angle
sensor voltage is outside the normal operating range of 0.25-
2.7 volts. Refer to
Table 4-32.
This may be caused by:
●
Short to ground in harness between sensor and elec-
tronic control module.
●
Short to voltage in harness between sensor and elec-
tronic control module.
●
Failed sensor.
If this code occurs, the engine may stop running. The engine
may still be restarted and ridden to the dealership for repair.
DIAGNOSTICS
Diagnostic Notes
The reference numbers below correlate with the circled num-
bers on the Code 44 flow charts.
1.
Use HARNESS CONNECTOR TEST KIT (Part No. HD-
41404), gray pin probes and patch cord.
2.
Connect BREAKOUT BOX (Part No. HD-42682) to ECM.
See
4.6 BREAKOUT BOX
.
Figure 4-57. Bank Angle Sensor Operation
Table 4-32. Bank Angle Sensor Voltage
MODE
VOLTS
Run mode
0.25-2.7
Disable mode
2.8-4.8
Figure 4-58. Bank Angle Sensor
b1085x4x
Run Mode 0.25-2.7 volts
Disable Mode 2.8-4.8 volts
Weighted pendulum
8895
Summary of Contents for 2004 XB9S
Page 2: ......
Page 35: ...D 2 2004 Buell Lightning Appendix D HOME Rear Brake Systems Top View b1115xbsx ...
Page 36: ...2004 Buell Lightning Appendix D D 3 HOME Rear Brake Systems Left Side View b1116xcsx ...
Page 44: ...2004 Buell Lightning Appendix D D 11 HOME Clutch Cable Right Side View b1124xasx ...
Page 47: ...HOME NOTES ...
Page 49: ......
Page 103: ......
Page 201: ...HOME NOTES ...
Page 203: ......
Page 275: ...HOME NOTES ...
Page 307: ...HOME NOTES ...
Page 311: ...HOME NOTES ...
Page 351: ...HOME NOTES ...
Page 441: ......
Page 463: ...HOME NOTES ...
Page 465: ......
Page 517: ...HOME NOTES ...
Page 519: ......
Page 595: ...HOME NOTES ...
Page 597: ......