5-6
2004 Buell Lightning: Starter
HOME
Starter Test 4: Nothing Clicks
Check for ground at
relay Terminal 85.
Ground present?
YES
5832
Check for battery voltage at starter
relay Terminal 86 from starter button.
Battery voltage present?
Check for battery voltage from
starter button (BK/R wire at
connector [22]). Battery voltage
present with starter button pressed?
NO
Substitute good
relay or test relay.
YES
NO
Substitute good
starter relay or test
relay.
YES
Check for battery voltage to starter
button (W/BK wire at connector [22]).
Battery voltage present?
NO
Repair wiring
from starter
button to relay.
YES
Repair wiring to
starter button.
NO
Replace right han-
dlebar switchgear.
YES
5831
5816
5831
Inspect Starter
Interlock Circuit
or Correct
Relay Ground.
5828
4
3
3