PS07569 Plasma 375 Plasma Cutter Kit Assembly & Operating Instructions Manual
8
For thin materials reduce the amperage setting to get the best cutting quality, reduce excessive warping
and to extend the life of the electrode and nozzle.
Do not rapidly switch the torch trigger on and off; this will damage the pilot arc system and work piece.
The plasma cutter’s working air pressure range is 40-90psi. The internal pressure switch will shut off
when air pressure falls below 50psi. The switch only works when the pressure rises to 50psi or above.
Every 4-8 hours, check the air filter on your air supply and remove excess moisture. Too much moisture
in the cutter or torch may lead to operational trouble.
Always unplug the power supply before checking for and removing moisture.
Never allow a person with a cardiac pacemaker close to the working area without the permission of a
doctor. The magnetic field produced by plasma cutters during operation can disrupt pacemakers and
similar devices.
Never clean the slag off the torch head by hitting it against a hard object.
SERVICE
Tool service must be performed only by qualified repair personnel.
Service or maintenance by unqualified
personnel could result in a risk of injury.
When servicing a tool, use only identical replacement parts and follow instructions in the manual.
Use
of unauthorized parts or failure to follow Maintenance Instructions may create a risk of shock or injury.
Before using this tool, you need to become familiar with its operation.
If you are unsure about the
operation of the tool, or have any questions about its proper use, call the Customer Service Department at
1-888-287-6981. Follow these instructions for safe handling of the tool:
•
Be sure your work area is clean and secure.
Be sure the area is free from all foreign material, nails,
staples, or any other material
.
•
Always use the appropriate safety gear when operating.
Including but not limited to, goggles, dust
mask or respirator.